ADF Web AXIS HD67804-KNX-B2 User Manual

Canopen / knx - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.001
English
CANopen / KNX - Converter
(Order Code: HD67804-KNX-B2)
for Website information:
www.adfweb.com?Product=HD67804
for Price information:
www.adfweb.com?Price=HD67804-KNX-B2
Benefits and Main Features:
Very easy to configure
Electrical isolation
Temperature range: -40°C/85°C (-40°F/185°F)
User Manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
User Manual CANopen / KNX
Document code: MN67804_ENG
For others KNX products, see also the following links:
Converter KNX to
www.adfweb.com?Product=HD67801
www.adfweb.com?Product=HD67802
www.adfweb.com?Product=HD67803
www.adfweb.com?Product=HD67807
www.adfweb.com?Product=HD67808
www.adfweb.com?Product=HD67809
www.adfweb.com?Product=HD67810
www.adfweb.com?Product=HD67811
www.adfweb.com?Product=HD67812
www.adfweb.com?Product=HD67813
www.adfweb.com?Product=HD67814
www.adfweb.com?Product=HD67815
www.adfweb.com?Product=HD67818
www.adfweb.com?Product=HD67820
Do you have an your customer protocol?
www.adfweb.com?Product=HD67004
Do you need to choose a device? do you want help?
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
in India
in India
in India
in India
Revision 1.001
Pagina 1 di 29
(BACnet Master)
(BACnet Slave)
(CAN)
(EtherNet/IP)
(DeviceNet Master)
(DeviceNet Slave)
(J1939)
(M-Bus Master/wM-Bus)
(Modbus Master)
(Modbus Slave)
(Modbus TCP Master)
(Modbus TCP Slave)
(PROFINET Slave)
(SNMP)
Phone +39.0438.30.91.31

Advertisement

Table of Contents
loading

Summary of Contents for ADF Web AXIS HD67804-KNX-B2

  • Page 1 User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 1 di 29 Industrial Electronic Devices User Manual Revision 1.001 English CANopen / KNX - Converter (Order Code: HD67804-KNX-B2) for Website information: www.adfweb.com?Product=HD67804 for Price information: www.adfweb.com?Price=HD67804-KNX-B2 For others KNX products, see also the following links: Benefits and Main Features: Converter KNX to Very easy to configure...
  • Page 2: Table Of Contents

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 2 di 29 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that Page you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 3 di 29 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 4 di 29 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 5 di 29 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67804-KNX-B2 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6: Characteristics

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 6 di 29 Industrial Electronic Devices CHARACTERISTICS: The HD67804 is a CANopen / KNX Converter. It has the following characteristics: Up to 1440 bytes in reading and 1440 bytes in writing; Triple isolation between KNX - Power Supply, KNX –...
  • Page 7: Power Supply

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 7 di 29 Industrial Electronic Devices POWER SUPPLY: The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin Vmax Consumption at 24V DC:...
  • Page 8: Function Modes

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 8 di 29 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the ‘Dip1 of Dip-Switch A’: The first, with ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip1 of Dip-Switch A’...
  • Page 9: Leds

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 9 di 29 Industrial Electronic Devices LEDS: The device has got six LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode ON: Device powered...
  • Page 10: Canopen

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 10 di 29 Industrial Electronic Devices CANOPEN: For terminate the CANopen line with a 120Ω resistor it is necessary that the Dip1 of ‘Dip-Switch C’ is at ON position. Cable characteristics: DC parameter: Impedance...
  • Page 11: Knx

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 11 di 29 Industrial Electronic Devices KNX: KNX is the standard that allows the automated and decentralized management of the technologic plans of a big typology of structures: commercial buildings, factories, houses, public locals, schools and so on. KNX can be used in all the applications and functions for the building automations: from lighting to control dampers, to the security, to the heating monitoring, to the conditioning, to the hydric control and alarms, to energy management and so on.
  • Page 12: Ethernet

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 12 di 29 Industrial Electronic Devices ETHERNET (PROGRAMMING PORT): The Ethernet ports are used for programming the device. The Ethernet connection must be made using Connector2 of HD67804-KNX-B2 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m.
  • Page 13: Use Of Compositor Sw67804

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 13 di 29 Industrial Electronic Devices USE OF COMPOSITOR SW67804: To configure the Converter, use the available software that runs with Windows called SW67804. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 14: New Project / Open Project

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 14 di 29 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a Programmable “CANopen / KNX - Converter”...
  • Page 15: Software Options

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 15 di 29 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor. In the section “Language”...
  • Page 16: Set Communication

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 16 di 29 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, KNX and CANopen. By Pressing the “Set Communication” button from the main window for SW67804 (Fig. 2) the window “Set Communication”...
  • Page 17: Knx Access

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 17 di 29 Industrial Electronic Devices KNX ACCESS: By pressing the “KNX Access” button from the main window for SW67804 (Fig. “KNX Access” window appears (Fig. 4). The means of the fields are: If the field “Enable”...
  • Page 18 User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 18 di 29 Industrial Electronic Devices In the field “Poll Time” the delay in ms between two KNX commands is defined (if “On Timer” is checked); In the field “Position” insert the address of the internal array where placing the information; In the field “Bit Mode”...
  • Page 19: Set Sdo Server

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 19 di 29 Industrial Electronic Devices SET SDO SERVER: By pressing the “Set SDO Server” button from the main window for SW67804 (Fig. 2) the window “Set SDO Server Access” appears (Fig.
  • Page 20: Set Sdo Client

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 20 di 29 Industrial Electronic Devices SET SDO CLIENT: By pressing the “Set SDO Client” button from the main window for SW67804 (Fig. 2) the window “Set SDO Client Access” appears (Fig. 6a and 6b).
  • Page 21 User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 21 di 29 Industrial Electronic Devices The data of the columns in the “SDO Write” have the following meanings: In the field "Device ID" insert the ID of the device used to write the data;...
  • Page 22: Set Pdo Access

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 22 di 29 Industrial Electronic Devices SET PDO ACCESS: By pressing the “Set PDO Access” button from the main window for SW67804 (Fig. 2) the window “Set PDO Access” appears (Fig. 7a and 7b).
  • Page 23: Eds File

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 23 di 29 Industrial Electronic Devices The data of the columns in the “Transmit PDO” have the following meanings: In the Field "Cob-ID" the address for the PDO is defined;...
  • Page 24: Update Device

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 24 di 29 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary.
  • Page 25 User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 25 di 29 Industrial Electronic Devices If you know the actual IP address of the device, you have to use this procedure: Turn on the Device with the Ethernet cable inserted; Insert the actual IP of the Converter;...
  • Page 26: Mechanical Dimensions

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 26 di 29 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 10: Mechanical dimensions scheme for HD67804-KNX-B2 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 27: Ordering Informations

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 27 di 29 Industrial Electronic Devices ORDERING INFORMATIONS: The ordering part number is formed by a valid combination of the following: HD67804 – KNX – B 2 Connectors Type 2: Fixed 5mm Screw Terminal Enclosure Type B: 4M, 35mm DIN Rail mounting...
  • Page 28: Disclaimer

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 28 di 29 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 29: Warranties And Technical Support

    User Manual CANopen / KNX Document code: MN67804_ENG Revision 1.001 Pagina 29 di 29 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com.

Table of Contents