ADF Web HD67876-A1-2A User Manual

ADF Web HD67876-A1-2A User Manual

Io-link / profinet slave - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.000
English
IO-Link / PROFINET Slave - Converter
(Order Code: HD67876-A1-2A, HD67876-A1-4A,
HD67876-A1-2B, HD67876-A1-2A-2B)
for Website information:
www.adfweb.com/?Product=HD67876
for Price information:
www.adfweb.com/?Price=HD67876-A1-2A
www.adfweb.com/?Price=HD67876-A1-4A
www.adfweb.com/?Price=HD67876-A1-2B
www.adfweb.com/?Price=HD67876-A1-2A-2B
Benefits and Main Features:
Triple electrical isolation
Two Ethernet ports
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
User Manual IO-Link / PROFINET Slave
Document code: MN67876_ENG
Revision 1.000
For others IO-Link devices, see also the following links:
IO-Link from/to ...
www.adfweb.com?Product=HD67860
www.adfweb.com?Product=HD67861
www.adfweb.com?Product=HD67862
www.adfweb.com?Product=HD67863
www.adfweb.com?Product=HD67864
www.adfweb.com?Product=HD67865
www.adfweb.com?Product=HD67866
www.adfweb.com?Product=HD67867
www.adfweb.com?Product=HD67868
www.adfweb.com?Product=HD67869
www.adfweb.com?Product=HD67870
www.adfweb.com?Product=HD67871
www.adfweb.com?Product=HD67872
www.adfweb.com?Product=HD67873
www.adfweb.com?Product=HD67874
www.adfweb.com?Product=HD67875
www.adfweb.com?Product=HD67877
www.adfweb.com?Product=HD67878
Do you have an your customer protocol?
See the following links:
www.adfweb.com?Product=HD67876
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
Page 1 of 38
(Modbus Master)
(Modbus Slave)
(Modbus TCP Master)
(Modbus TCP Slave)
(BACnet Master)
(BACnet Slave)
(CAN)
(CANopen)
(DeviceNet Master)
(DeviceNet Slave)
(EtherNet/IP Master)
(EtherNet/IP Slave)
(J1939)
(MQTT)
(NMEA0183)
(NMEA2000)
(SNMP Manager)
(SNMP Agent)
Phone +39.0438.30.91.31

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67876-A1-2A and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web HD67876-A1-2A

  • Page 1 Revision 1.000 Page 1 of 38 User Manual Revision 1.000 English IO-Link / PROFINET Slave - Converter (Order Code: HD67876-A1-2A, HD67876-A1-4A, HD67876-A1-2B, HD67876-A1-2A-2B) for Website information: www.adfweb.com/?Product=HD67876 For others IO-Link devices, see also the following links: for Price information: IO-Link from/to …...
  • Page 2: Table Of Contents

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 2 of 38 INDEX: UPDATED DOCUMENTATION: Page Dear customer, we thank you for your attention and we remind you that INDEX you need to check that the following document is: UPDATED DOCUMENTATION Updated REVISION LIST...
  • Page 3: Security Alert

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 3 of 38 SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 4 of 38 EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 5 of 38 CONNECTION SCHEME: Figure 1a: Connection scheme for HD67876-A1-2A ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6 User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 6 of 38 Figure 1b: Connection scheme for HD67876-A1-4A ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 7 User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 7 of 38 Figure 1c: Connection scheme for HD67876-A1-2B ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 8 User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 8 of 38 Figure 1d: Connection scheme for HD67876-A1-2A-2B ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 9: Characteristics

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 9 of 38 CHARACTERISTICS: The HD67876-A1 is a IO-Link / PROFINET Slave converter. It allows the following characteristics: Up to 1440 bytes in reading and 1440 bytes in writing; Two-directional information between PROFINET and IO-Link;...
  • Page 10: Power Supply

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 10 of 38 POWER SUPPLY: The devices can be powered between a wide range of tensions. For more details see the two tables below. Vmin Vmax HD67876-A1-xx Consumption at 24V DC:...
  • Page 11: Function Modes

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 11 of 38 FUNCTION MODES: The device has got two functions mode depending of the position of the Dip1 of ‘Dip-Switch A’: The first, with Dip1 in Off position (factory setting), is used for the normal working of the device. The second, with Dip1 in On position, is used for upload the Project/Firmware.
  • Page 12: Leds

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 12 of 38 LEDS: The device has got five LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 13: Io-Link

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 13 of 38 IO-LINK IO-Link is the first globally standardized IO technology (IEC 61131-9) that communicates from the controller down to the lowest automation level. This universally applicable interface is a fieldbus-neutral point-to-point connection which uses standard unshielded cables. IO-Link sends all the sensor and actuator signals to the controller and in turn carries controller data to the sensor/actuator level with revolutionary consequences.
  • Page 14: Aux Power Supply

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 14 of 38 IO-L LASS IO-Link Class B devices uses 5 pins on connectors and they require an additional aux power supply used for the actuation. These devices are normally actuators.
  • Page 15: Ethernet

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 15 of 38 ETHERNET: The Ethernet connection must be made using Connector5 of HD67876-A1 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m.
  • Page 16: Use Of Compositor Sw67876

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 16 of 38 USE OF COMPOSITOR SW67876: To configure the Converter, use the available software that runs with Windows called SW67876. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 17: New Project / Open Project

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 17 of 38 NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “IO-Link / PROFINET Slave - Converter”...
  • Page 18: Software Options

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 18 of 38 SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor. In the section “Language”...
  • Page 19 User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 19 of 38 In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 20: Set Communication

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 20 of 38 SET COMMUNICATION: This section defines the fundamental communication parameters of Modbus TCP. By Pressing the “Set Communication” button from the main window for SW67876(Fig.
  • Page 21: Io-Link Set Access

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 21 of 38 IO-LINK SET ACCESS: By Pressing the “IO-Link Set Access” button from the main window for SW67876 (Fig. 2) the window “IO-Link Set Access” appears (Fig. 4). This section is used to define the list of IO-Link variables from/to which take/map the data of PROFINET.
  • Page 22 User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 22 of 38 In the “List of IO-Link Channel” section it is possible to configure all the IO-Link channels of the converter (Fig. 5). Figure 5: “List of IO-Link Channel” section The meanings of the fields are: In the field “Channels”...
  • Page 23 User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 23 of 38 By clicking on “Insert IODD”, the window “IO-Link IODD Catalog” appears (Fig. 6). This section is used to select an IO-Link device. By clicking on “Add IODD”...
  • Page 24 User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 24 of 38 The “Process Data” section is used to define the IO-Link process data from/to which take/map the data of PROFINET (Fig. 7). Figure 7: “Process Data” section The meanings of the fields are: In the field “Id”...
  • Page 25 User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 25 of 38 The “Device Function – Variables” section is used to define the IO-Link parameters from/to which take/map the data of PROFINET (Fig. 8). Figure 8: “Device Function - Variables”...
  • Page 26 User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 26 of 38 In the field “Default” the default value of the IO-Link parameter is defined; In the field “Value” the starting value of the IO-Link parameter is defined; In the field “Description”...
  • Page 27 User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 27 of 38 The “Events” section is used to define the IO-LINK events to which map the data of PROFINET (Fig. 10). Figure 10: “Events” section The meanings of the fields are: In the field “Code”...
  • Page 28 User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 28 of 38 In “Device Identity” section (Fig.11) and “Transport Identity” section (Fig. 12), the main features of the selected IO-Link device are reported. These characteristics are read from the IODD file. Figure 11: “Transport Layers”...
  • Page 29: Profinet Xml

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 29 of 38 PROFINET XML: By Pressing the “PROFINET XML” button from the main window for SW67876 (Fig. 2) it is possible to generate the xml file to be imported into the master PROFINET (Fig.
  • Page 30: Update Device

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 30 of 38 UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port.
  • Page 31 User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 31 of 38 Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67876 device. Warning: If Fig.
  • Page 32: Plc Configuration

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 32 of 38 PLC CONFIGURATION: The configuration and commissioning of the PROFINET Converter as described on the following pages was accomplished with the help of the TIA Portal software of Siemens.
  • Page 33 User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 33 of 38 2) Import the module in the network; connect the device to the PLC network and edit the parameters of IP, station name etc. ADFweb.com Srl –...
  • Page 34 User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 34 of 38 3) Load the configuration into the PLC. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 35: Mechanical Dimensions

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 35 of 38 MECHANICAL DIMENSIONS: Figure 16: Mechanical dimensions scheme for HD67876-A1-xx ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 36: Ordering Informations

    A: 1M, 35mm DIN Rail mounting Device Family HD67876: IO-Link / PROFINET Slave - Converter Order Code: HD67876-A1-2A IO-Link / PROFINET Slave – Converter (IO-Link ports: 2 x Class A) Order Code: HD67876-A1-4A IO-Link / PROFINET Slave – Converter (IO-Link ports: 4 x Class A) Order Code: HD67876-A1-2B IO-Link / PROFINET Slave –...
  • Page 37: Disclaimer

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 37 of 38 DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 38: Warranties And Technical Support

    User Manual IO-Link / PROFINET Slave Industrial Electronic Devices Document code: MN67876_ENG Revision 1.000 Page 38 of 38 WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com.

This manual is also suitable for:

Hd67876-a1-4aHd67876-a1-2bHd67876-a1-2a-2b

Table of Contents