Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.000
English
DALI / DMX - Converter
(Order Code: HD67838-B2-Y, HD67838-B2-N)
for Website information:
www.adfweb.com?Product=HD67838
for Price information:
www.adfweb.com?Price=HD67838-B2
Benefits and Main Features:
Very easy to configure
Electrical isolation
Temperature range: -40°C/85°C (-40°F/185°F)
User Manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
User Manual DALI / DMX
Document code: MN67838_ENG
For others DALI products, see also the following links:
Converter DALI to
www.adfweb.com?Product=HD67822
www.adfweb.com?Product=HD67831
www.adfweb.com?Product=HD67832
www.adfweb.com?Product=HD67833
www.adfweb.com?Product=HD67834
www.adfweb.com?Product=HD67835
www.adfweb.com?Product=HD67836
www.adfweb.com?Product=HD67837
www.adfweb.com?Product=HD67839
www.adfweb.com?Product=HD67840
www.adfweb.com?Product=HD67842
www.adfweb.com?Product=HD67843
www.adfweb.com?Product=HD67844
www.adfweb.com?Product=HD67845
www.adfweb.com?Product=HD67848
www.adfweb.com?Product=HD67849
www.adfweb.com?Product=HD67850
Do you have an your customer protocol?
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
in India
in India
in India
in India
Revision 1.000
Pagina 1 di 38
(KNX)
(RS485)
(BACnet/IP Master)
(BACnet/IP Slave)
(CAN)
(CANopen)
(DeviceNet Master)
(DeviceNet Slave)
(Ethernet)
(EtherNet/IP)
(Modbus Master)
(Modbus Slave)
(Modbus TCP Master)
(Modbus TCP Slave)
(PROFINET)
(SNMP Manager)
(SNMP Agent)
Phone +39.0438.30.91.31

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Axis HD67838-B2-Y and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADF Web Axis HD67838-B2-Y

  • Page 1 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 1 di 38 Industrial Electronic Devices User Manual Revision 1.000 English DALI / DMX - Converter (Order Code: HD67838-B2-Y, HD67838-B2-N) for Website information: www.adfweb.com?Product=HD67838 for Price information: www.adfweb.com?Price=HD67838-B2 For others DALI products, see also the following links: Converter DALI to www.adfweb.com?Product=HD67822 (KNX)
  • Page 2: Updated Documentation

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 2 di 38 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that Page you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 3 di 38 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 4 di 38 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 5 di 38 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67838-B2 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 6 di 38 Industrial Electronic Devices CHARACTERISTICS: The HD67838 is a DALI / DMX - Converter. It has the following characteristics: Up to 64 devices on DALI bus; Configurator for DALI network/devices; Isolation between DALI –...
  • Page 7: Power Supply

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 7 di 38 Industrial Electronic Devices POWER SUPPLY: The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin Vmax Consumption at 24V DC:...
  • Page 8: Function Modes

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 8 di 38 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the ‘Dip1 of Dip-Switch A’: The first, with ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip1 of Dip-Switch A’...
  • Page 9 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 9 di 38 Industrial Electronic Devices LEDS: The device has got five LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 10 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 10 di 38 Industrial Electronic Devices DALI: DALI stands for “Digital Addressable Lighting Interface” and it is an interface protocol for digital communication between electronic lighting equipment (electronic ballasts, transformers, etc.). With the right choice of individual DALI components an extremely wide range of requirements can be met, from operating the lighting system from a simple light switch to lighting management systems for entire office complexes with thousands of light sources.
  • Page 11 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 11 di 38 Industrial Electronic Devices RS485: For terminate the RS485 line with a 120Ω resistor it is necessary to put ON dip 1, like in figure. The maximum length of the cable should be 1200m (4000 feet). Here some codes of cables: Belden: p/n 8132 - 2x 28AWG stranded twisted pairs conductor + foil shield + braid shield;...
  • Page 12 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 12 di 38 Industrial Electronic Devices ETHERNET: The Ethernet port is used for programming DALI network and for programming the converter. The Ethernet connection must be made using Connector2 of HD67838-B2 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m.
  • Page 13 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 13 di 38 Industrial Electronic Devices USE OF COMPOSITOR SW67838: To configure the Converter, use the available software that runs with Windows called SW67838. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 14: New Configuration / Open Configuration

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 14 di 38 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a Programmable “DALI / DMX - Converter”...
  • Page 15: Software Options

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 15 di 38 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 16 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 16 di 38 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software. ADFweb.com Srl –...
  • Page 17: Set Communication

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 17 di 38 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of DMX and DALI buses. By Pressing the “Set Communication” button from the main window for SW67838 (Fig. 2) the window “Set Communication”...
  • Page 18: Dali Access

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 18 di 38 Industrial Electronic Devices DALI ACCESS: By pressing the “DALI Access” button from the main window for SW67838 (Fig. 2) the window “Select the DALI Device Present in the Network”...
  • Page 19 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 19 di 38 Industrial Electronic Devices DMX DEFAULT VALUE: By pressing the “DMX Default Value” button from the main window for SW67838 (Fig. 2) the “DMX Default Value” window appears (Fig. 5). In this section it is possible to define the default value for each channel of the DMX array when the converter is turned ON.
  • Page 20: Update Device

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 20 di 38 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary.
  • Page 21 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 21 di 38 Industrial Electronic Devices Note: When you install a new version of the software, if it is the first time it is better you do the update of the Firmware in the HD67838 device.
  • Page 22: Use Of Dali Console Software

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 22 di 38 Industrial Electronic Devices USE OF DALI CONSOLE SOFTWARE: To configure DALI network and test the communication, it is possible to use the available software that runs with Windows called “DALI Console”.
  • Page 23: Structure Of The Software

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 23 di 38 Industrial Electronic Devices STRUCTURE OF THE SOFTWARE: The software layout is very simple and it is structured in this way: “Menu bar” (Fig. 9, Point 1): it is possible to open the setup window (“Setup”...
  • Page 24 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 24 di 38 Industrial Electronic Devices SETUP: This section defines the connection’s parameters to the Ethernet side of the HD67838 converter. By Pressing the “Setup” button from the menu bar of the DALI Console software, the “SETUP” window appears (Fig. 10). Figure 10: “Setup”...
  • Page 25: Network Setting

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 25 di 38 Industrial Electronic Devices NETWORK SETTING: By pressing the button in the Network view, it is possible to scan the full DALI network and find all the DALI devices, the groups set and the scenes configured.
  • Page 26 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 26 di 38 Industrial Electronic Devices The means of the fields for the “CONTROL COMMANDS” section are: In the “POWER CONTROL” bar it is possible to change the actual ADV of the selected DALI device; In the field “COMMAND”...
  • Page 27 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 27 di 38 Industrial Electronic Devices ROUPS The means of the fields for the “CONTROL COMMANDS” section are: In the “POWER CONTROL” bar it is possible to change the actual ADV of the selected DALI group; In the field “COMMAND”...
  • Page 28 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 28 di 38 Industrial Electronic Devices CENES By selecting a DALI scene from the Network view, it is possible to see the devices that have programmed the selected scene. It is also possible to activate it by pressing the “ACTIVATE SCENE X”...
  • Page 29 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 29 di 38 Industrial Electronic Devices LL DEVICES ROADCAST The means of the fields for the “CONTROL COMMANDS” section are: In the “POWER CONTROL” bar it is possible to change the actual ADV of the entire DALI network;...
  • Page 30: Dmx Mapping

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 30 di 38 Industrial Electronic Devices DMX MAPPING: Internally to the converter, there is a fixed map that allows to control DALI lamps with a DMX controller/console. Structure of the DMX map (data that the DMX controller can send to the converter) ADV SETTING FOR SINGLE DALI NODES DMX channel Description...
  • Page 31 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 31 di 38 Industrial Electronic Devices ADV to set on DALI node 17 ADV to set on DALI node 18 ADV to set on DALI node 19 ADV to set on DALI node 20 ADV to set on DALI node 21 ADV to set on DALI node 22 ADV to set on DALI node 23...
  • Page 32 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 32 di 38 Industrial Electronic Devices ADV to set on DALI node 42 ADV to set on DALI node 43 ADV to set on DALI node 44 ADV to set on DALI node 45 ADV to set on DALI node 46 ADV to set on DALI node 47 ADV to set on DALI node 48...
  • Page 33 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 33 di 38 Industrial Electronic Devices ADV SETTING FOR GROUPS DMX channel Description ADV to set on Group 0 ADV to set on Group 1 ADV to set on Group 2 ADV to set on Group 3 ADV to set on Group 4 ADV to set on Group 5...
  • Page 34 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 34 di 38 Industrial Electronic Devices ADV SETTING (BROADCAST) DMX channel Description ADV to set Note: The range of ADV can be from 0 to 255. The minimum and the maximum value of the ADV for each DALI node depends on the setting of the DALI node.
  • Page 35: Mechanical Dimensions

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 35 di 38 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 15: Mechanical dimensions scheme for HD67838-B2-x ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 36: Ordering Informations

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 36 di 38 Industrial Electronic Devices ORDERING INFORMATIONS: The ordering part number is formed by a valid combination of the following: HD67838 – B 2 - x DALI Bus power supply Y: present (the converter feeds the DALI bus) N: not present (the converter doesn’t feed the DALI bus) Connectors Type...
  • Page 37 User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 37 di 38 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 38: Warranties And Technical Support

    User Manual DALI / DMX Document code: MN67838_ENG Revision 1.000 Pagina 38 di 38 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com.

This manual is also suitable for:

Axis hd67838-b2-n

Table of Contents