Falcon DOMINATOR PLUS E3830 Design, Installation And Servicing Instructions

Falcon DOMINATOR PLUS E3830 Design, Installation And Servicing Instructions

Hide thumbs Also See for DOMINATOR PLUS E3830:

Advertisement

Quick Links

E3830, E3860 & E3865 DOMINATOR PLUS
Fryers
INSTALLATION and SERVICING INSTRUCTIONS
IMPORTANT
The installer must ensure that the installation of the appliance is in conformity with these
instructions and National Regulations in force at the time of installation. Particular attention
MUST be paid to:
Gas safety (Installation & Use) regulations
Health & Safety at work, etc Act
Local and National Building Regulations
This appliance has been UKCA/CE marked based on compliance with the relevant Electrical and
Electromagnetic Compatibility (EMC) Regulations/Directives for the voltages stated on the data plate.
WARNING - TO PREVENT SHOCKS, ALL APPLIANCES, GAS OR ELECTRIC, MUST BE EARTHED.
On completion of the installation, these instructions should be left with the Engineer-in- Charge for
reference during servicing. Further to this, The Users Instructions should be handed over to the User,
having had a demonstration of the operation and cleaning of the appliance.
IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND
COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES
MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.
PREVENTATIVE MAINTENANCE CONTRACT
To
obtain maximum performance from this unit regular servicing of the appliance should be undertaken to
ensure correct operation, it is functioning as intended, and safe to use. We recommend servicing in
accordance with SFG20 Maintenance Schedules and as a minimum, after 2,500 hours of use, or annually,
whichever comes
first and
may then be made at agreed intervals to carry out adjustments and repairs.
WEEE Directive Registration No. WEE/DC0059TT/PRO
At end of unit life, dispose of appliance and any replacement parts in a safe manner,
via a licenced waste handler. Units are designed to be dismantled easily and
recycling of all material is encouraged whenever practicable.
Falcon Foodservice Equipment
HEAD OFFICE AND WORKS
Wallace View, Hillfoots Road, Stirling.
FK9 5PY. Scotland.
Phone: 01786 455200
that a maintenance contract be arranged with an appointed service contact. Visits
I.E.E. Regulations for Electrical Installations
Electricity at Work Regulations
Fire precaution Act
T100774 Ref. 18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DOMINATOR PLUS E3830 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Falcon DOMINATOR PLUS E3830

  • Page 1 At end of unit life, dispose of appliance and any replacement parts in a safe manner, via a licenced waste handler. Units are designed to be dismantled easily and recycling of all material is encouraged whenever practicable. T100774 Ref. 18 Falcon Foodservice Equipment HEAD OFFICE AND WORKS Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.
  • Page 2 IMPORTANT INFORMATION ELECTRICAL SAFETY AND ADVICE REGARDING SUPPLEMENTARY ELECTRICAL PROTECTION Commercial kitchens and foodservice areas are environments where electrical appliances may be located close to liquids, or operate in and around damp conditions or where restricted movement for installation and service is evident.
  • Page 3: Section 1 - Installation

    SECTION 1 – INSTALLATION UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER. Please ensure that any plastic coatings are removed prior to use. Before operation, the pan requires to be thoroughly cleaned and dried. Discolouration of heated parts is caused by factory testing to ensure a satisfactory unit.
  • Page 4: Section 2 - Assembly And Commissioning

    SECTION 2 - ASSEMBLY and COMMISSIONING ASSEMBLY The appliance is supplied complete and ready to be connected to the mains supply. Position unit in desired location and level it. Turn lower section of each leg clockwise to raise corresponding corner height or anti-clockwise to lower it. Castors Undo grub screw and use a spanner to adjust the castor height.
  • Page 5: Section 3 - Servicing And Maintenance

    2. Serial number – found on data plate 3. Brief description of the issue To contact Falcon for a warranty issue dial (UK only) 01786 455 200 and select Warranty Issues from the menu. BEFORE ATTEMPTING ANY MAINTENANCE TASK, ISOLATE THE APPLIANCE AT THE MAIN SUPPLY.
  • Page 6 ELECTRICAL CONTROL GEAR The mains terminals are located at rear of unit. The contactor(s) are contained within a box at the front. To gain access, open door and remove cover panel behind. The control thermostat(s) and neon lamps are mounted on the facia panel, which is secured by four fixings. NEON INDICATOR LAMPS These must be replaced by new lamps in event of failure.
  • Page 7: Section 4 - Spares

    SECTION 4 - SPARES When ordering spares, quote the unit type and serial number. This information will be found on data plate located on cover panel behind door. An identity label is also provided on front frame.
  • Page 8 E3830 WIRING DIAGRAM...
  • Page 9 E3830 CIRCUIT DIAGRAM...
  • Page 10 E3860 WIRING DIAGRAM...
  • Page 11 E3860 CIRCUIT DIAGRAM...
  • Page 12 E3865 WIRING DIAGRAM...
  • Page 13 E3865 CIRCUIT DIAGRAM...

This manual is also suitable for:

Dominator plus e3860Dominator plus e3865

Table of Contents