Advertisement

E3840/E3840F FRYERS
INSTALLATION, SERVICING
and USER INSTRUCTIONS
IMPORTANT
The installer must ensure that the installation of the appliance is in conformity with these instructions
and National Regulations in force at the time of installation.
Particular attention MUST be paid to -
BS7671 IEE Wiring Regulations
Electricity at Work Regulations
Health And Safety At Work Act
Fire Precautions Act
This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC
directives for the voltages stated on the data plate.
WARNING -THIS APPLIANCE MUST BE EARTHED
On completion of the installation these instructions should be left with the Engineer-in-Charge for
reference during servicing. Further to this, The Users Instructions should be handed over to the User,
having had a demonstration of the operation and cleaning of the appliance.
IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING
AND COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED
PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.
PREVENTATIVE MAINTENANCE CONTRACT
In order to obtain maximum performance from this unit we would recommend that a Maintenance
Contract be arranged with SERVICELINE. Visits may then be made at agreed intervals to carry out
adjustments and repairs. A quotation will be given upon request to the SERVICELINE contact
numbers below.
WEEE Directive Registration No. WEE/DC0059TT/PRO
At end of unit life, dispose of appliance and any replacement parts in a safe manner, via
a licenced waste handler. Units are designed to be dismantled easily and recycling of all
material is encouraged whenever practicable.
Falcon Foodservice Equipment
HEAD OFFICE AND WORKS
Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.
SERVICELINE CONTACT
Phone: 01438 363 000
Fax: 01438 369 900
T100805 Ref. 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E3840 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Falcon E3840

  • Page 1 E3840/E3840F FRYERS INSTALLATION, SERVICING and USER INSTRUCTIONS IMPORTANT The installer must ensure that the installation of the appliance is in conformity with these instructions and National Regulations in force at the time of installation. Particular attention MUST be paid to -...
  • Page 2 IMPORTANT INFORMATION Warranty Policy Shortlist Warranty does not cover :- Correcting faults caused by incorrect installation of a product. Where an engineer cannot gain access to a site or a product. Repeat commission visits. Replacement of any parts where damage has been caused by misuse. Engineer waiting time will be chargeable.
  • Page 3: Section 1 - Installation

    Weight adjoining appliances. Model (mm) (mm) (mm) (kg) E3840 Fryer 1.3 VENTILATION E3840F Fryer The appliance ventilation requirements should be in line with national and local regulations. 1.2 SITING For multiple installations, requirements should be added Each unit must be installed on a firm level floor in a together.
  • Page 4 Place element guard and baskets in pan. d) Level appliance and fit all service protection kits. (Anti-tilt kit, if ordered as accessory). Figure 3 – E3840 / 3840F - Additional Controls The following additional controls are located behind 2.2 CONNECTION TO AN ELECTRICAL SUPPLY cabinet door.
  • Page 5: Section 3 - Servicing And Conversion

    2.4 PRE-COMMISSIONING CHECK SECTION 3 - SERVICING AND CONVERSION 2.4.1 Checking Controller Operation To check operation of controls, refer to Using The BEFORE ATTEMPTING ANY SERVICING, TURN OFF Controller - Section 6.2.1. THE ELECTRICAL SUPPLY. TAKE STEPS TO ENSURE THAT THESE CANNOT BE INADVERTENTLY TURNED 2.4.2 Checking Oil Filtration Pump To check operation of oil filtration pump, refer to Section 7.
  • Page 6 3.5 MAINS ON and HEAT DEMAND NEONS SECTION 4 - SPARES a) Remove control panel by undoing fixings at top and When ordering spare parts, always quote the appliance bottom of control panel and unplug control panel. type and serial number. This information will be found on the data plate.
  • Page 7: Section 5 - Critical Dimensions

    SECTION 5 - CRITICAL DIMENSIONS Timer Pump Settings Set for 230V Set to 0.8 Set to 10 minutes Set to Wu...
  • Page 8: Section 6 - Operating Instructions

    No attempt must be made to operate the appliance during a power supply failure. E3840 - Manual control model. Please ensure that any plastic coated items are removed E3840F - Manual control model with built-in filtration.
  • Page 9: Starting The Filtration Process

    SECTION 7 - CHANGING/FILTERING THE OIL Warning 7.1.1 E3840F Models After filtering, wait 30 seconds before removing bucket. Note: With cabinet door open, switch is located at RH side of drain valve (Refer to Figure 3). When draining, ensure the oil has time to strain through strainer basket.
  • Page 10: Section 8 - Cleaning And Maintenance

    SECTION 8 - CLEANING and MAINTENANCE RECOMMENDATION 8.1 CLEANING THE APPLIANCE Personal protective equipment (PPE's) should be used 1. Carry out actions detailed in Section 8. when cleaning or handling medium within this appliance. 2. Switch unit OFF and drain fry pot. WARNING - NEVER PUMP WATER THROUGH THE 3.
  • Page 11: Section 9 - Cooking Hints

    8. After serving and when fryer has been turned off, replace lid to ensure that no foreign bodies can contaminate frying medium. E3840 / E3840F Control Panel Wiring Diagram FIT TO ELEMENT BOX FIT TO TERMINAL BLOCK CONNECTOR IN ELEMENT BOX...

This manual is also suitable for:

E3840f

Table of Contents