PC B L ayo u t
12VDC 7.2Ah Sealed
Lead Acid Battery
Panasonic LC-P127R2P
or Equivalent
The maximum
continuous
combined
current draw
from the +12V,
LAN + and
C+ terminals
must not
exceed 1 Amp
Output 1, 2, 3 and 4
Connection Terminals
12
Earth Connection
Spade For Surge
Protection
16-18 VAC
24VA
Accessory
12 VDC Supply
(750mA Fused)
LAN Devices
Connection
Terminals
(750mA Fused)
Output Devices
12VDC Supply
(2.5A Fused)
500mA
Ouput 5
Relay Output
24V D.C. 2Amp
RF Receiver
/ Keyswitch
Input
Zone Input
Terminals

Figure 20: Solution 6000-IP Board Layout

Relay COM
Terminal
Programming
Shunt
Bosch Security Systems 10/22 BLCC615R
Panel Cabinet
Tamper Circuit
Connection
Terminals
Battery
Charging
Globe
RS485 LAN
Termination
Shunt
4-Pin Socket
to LAN For
Service Keypad
Expansion Port
TCP/IP, GSM
Module
Connection
Default and
Direct Connect
Switch
Refer to
Documentation
For Dialer &
Status LED's
10-Pin Serial
Connection
Socket For Direct
Link / Flash
Programming
etc.