Flow direction marked in the cell must be
respected. Recirculation system must guarantee
the minimum flow stated in the Technical
Specifications Table.
Figure 5.
Vertical Installation Flow Direction
2.
The system flow detector activates if there is no
recirculation (flow) of water through the cell or if
flow is very low, whenever the cell entry valves
are open.
Figure 6.
System Flow Sensor Activation
WARNING
A pressure switch or mechanical flow detector palette is
additionally supplied with the unit which provides a redundant
security in absence of water flow through the cell.
The flow detector must be revised periodically as it is a mechanical
element.
3.3

Installing Control/Power Centers

NOTE: The control/power center should be located at or
near the equipment pad.
CAUTION
The control/power center is not to be considered as suitable for use
as service equipment. Therefore, it is required to have the appropriate
means of disconnection, circuit isolation, and/or branch circuit
protection installed upstream of the power center.
Locate the control/power center at least five (5) feet
or more away from pool/spa and five (5) feet off
the ground. All national, state, and local codes are
applicable.
NOTE: For Canadian installations, the control/power
center must be at least three (3) meters (9.8 feet)
away from the pool/spa and 1.5 meters (5 feet)
above the ground.