2
Start measurement: tap
Zeroing takes place.
Readings are displayed.
Draft
If the
display, a draft measurement is automatically started in parallel to
the flue gas measurement. In the
parallel draft measurement can be stopped/restarted. This draft
measurement is performed separately to a measurement of the
Draft
measurement type.
For the draught measurement, the minus connection for differential
pressure measurement must be free (ambient pressure, not closed).
3
Tap on the draught reading display
4
End measurement: tap
Automatic display after connection of one or more Smart Probe testo 115i
or testo 915i during flue gas measurement
If several temperature probes are connected in total (external probes and/or
testo 115i or testo 915i), the temperature probes are used for flue gas
measurement according to the following procedure.
The AT probe = external cable probe always has first priority.
.
measurement parameter is enabled in the reading
.
9 Performing the measurement
List
measurement data view, the
or
next to it.
57