TESTO Next-Gen 300 Instruction Manual page 10

Combustion analyzer
Hide thumbs Also See for Next-Gen 300:
Table of Contents

Advertisement

5 Specifications
The instrument can be used for measurements on CHP plants in accordance
with the first German Federal Immission Control Ordinance (BImschV).
In principle, the CO sensor can also be used for measurements on CHP
plants. If you carry out more than 50 measurements on CHP plants per year,
please contact your nearest Testo service center or send the instrument to
Testo Service for checking.
An NO
filter for the CO sensor can be ordered as a spare part to replace a
x
used filter.
The Next-Gen testo 300 is a measuring instrument which enables the
professional flue gas analysis of combustion systems, such as
small combustion plants (oil, gas, wood, coal)
The solid fuel measurement adapter (0600 9765) is required for
measurements on solid fuel systems. The adapter protects the
measuring instrument from harmful substances (dust, organic
compounds, etc.).
low-temperature and condensing boilers
gas heaters.
.
Using the instrument, these systems can be adjusted and checked for
compliance with the applicable limit values.
The instrument has been verified as a short-term measuring instrument and
should not be used as a safety (alarm) device.
The following tasks can also be carried out using the instrument:
Regulating the O
ensure optimum operation.
Draft measurement.
4Pa measurement.
Measuring and regulating the gas flow pressure in gas heaters.
Measuring and optimising the flow and return temperatures of heating
systems.
Measuring the CO concentration in the ambient air.
The instrument can be used for measurements on CHP plants in accordance
with the first German Federal Immission Control Ordinance (BImschV).
In principle, the CO sensor can also be used for measurements on CHP
plants. If you carry out more than 50 measurements on CHP plants per year,
please contact your nearest Testo service centre or send the instrument to
Testo Service for checking.
An NO
filter for the CO sensor can be ordered as a spare part to replace a used
x
filter.
10
, CO and CO
, NO, NO
2
2
values in combustion plants to
x

Advertisement