6. OPERATION (PRODUCTION)

Getting Started

This startup procedure assumes all necessary information has been entered in the Tool Database, Connector
Database, Profile Database, Condition Database, and Sequence Database. See the programming section for
details on entering data into these database tables. CBP screen examples are shown below. CMP screens are
similar.

Operator Interface

All selections on the computer monitor can be made either by touching the screen with a finger or by pointing
and left-clicking with the mouse. Alpha-numeric entries can be entered by the keyboard or by touching the
screen buttons provided. Data for some production screen entry fields can also be entered using the optional
barcode scanner. NOTE: A drop of moisture on the face of the touch screen may prevent normal operation until
it is removed.
Navigation between the primary functional screens is accomplished using the operator button toolbar along the
bottom of the screen and the drop-down menus located in toolbar at the top of the screen. The operator toolbar
along the bottom of screen contains buttons that link to the primary screens used by an operator during
production. The System drop-down menu located along the top toolbar contains buttons that link to the screens
used for system setup and maintenance. The Editors drop-down menu located along the top toolbar contains
buttons that link to the screens used for part and sequence setup (see Figure 19).
Certain screens and/or specific function buttons may not be available, depending on the user's access level.
See the User Access section for more information. Press the "Help" button on the top toolbar to view
information from the user manual.
During production pressing operation, only a single toolbar is displayed at the bottom of the screen. The
buttons on this toolbar provide access to the functions available during board processing. Some function
buttons may not be available, depending on the user's access level (see Figure 20).

Powering Up

The main power disconnect is mounted on the side (CBP) or rear (CMP) of the machine. Turning the switch to
the "OFF" position disconnects the incoming power. It can be locked out for safety and security proposes. Turn
it to the "ON" position to start the machine.