One common modification to the "Measure Board Thickness" condition is toggling the "Execute Once
Per Batch" option (see Figure 54) on or off based on how often board thickness should be measured
for the users application. Toggling the option off will cause board measurement to occur for every
board pressed. When the option is on, board measurement will only occur for the first board pressed in
the batch. Reloading the press sequence will start a new batch.
Another common modification to the "Measure Board Thickness" condition is to adjust the
measurement "Probe Height" to the correct height based on the measurement probe being used (see
Figure 55). The "Probe Height" can be adjusted by pressing the "Measure Board Settings" button in the
"When" operation box and entering a new value in the settings window.
PCB Verify – The PCB Verify condition requires the operator to scan or enter the board part number or
model number for verification prior to pressing the board. This Standard Template Condition and others
that involve a barcode scanner often need to be modified to accommodate the specific scanner. The
model number that the PCB will be verified against also must be customized.
Rev C
Figure 54
Figure 55
409-35001
56 of 92