TE Connectivity CBP-5T Mk II Customer's Manual page 50

Cxp connector press machines
Table of Contents

Advertisement

"Command Settings" – This button opens the "When" PPS Settings window (see Figure 50).
This window is used to set how the "When" operation should evaluate to "true" and which
command data to send for "Set" PPS commands. The settings options will vary base on the
"Command" selected. "Set" PPS commands will always cause the "When" operation to
evaluate to "true" as long as a valid response is received and no errors occur.
"Valid Response Received" / "Response Data Meets Condition"– (Only used for "Get"
type PPS commands) This toggle selects how the "When" operation should evaluate to
"true". If "Valid Response Received" is selected, the "When" operation will complete as
"true" as long as no communication errors occur when communicating with the PPS tool,
regardless of the data that is received back from the tool. If "Response Data Meets
Condition" is selected, the "When" operation will complete as "true" only if the data
received back from the PPS tool matches certain criteria specified by the user.
"When Pass/Fail Status =" – (Only available for "Get Pass Fail" command when
"Response Data Meets Condition" is selected) This dropdown selects which type of PPS
pass/fail response should cause the "When" condition to evaluate to "true".
"Pass data for pins that are..." – (Only available for "Get Pin States" and "Get Pin Mask"
commands when "Valid Response Received" is selected) This dropdown selects whether
data for pressed or not pressed pins should be passed on to the "Then" operation of the
condition.
Rev C
Figure 50
409-35001
50 of 92