Product Description; Product Features - Fire-Lite Alarms MS-5024 Installation, Operation And Maintenance Manual

Fire control communicator
Hide thumbs Also See for MS-5024:
Table of Contents

Advertisement

The MS-5024 is a combination control panel and digital communicator all on one circuit board. It is a five-zone panel
which uses conventional input devices. The panel accepts waterflow devices, two-wire smoke detectors, four-wire
smoke detectors, pull stations and other normally open contact devices. Outputs include two Notification Appliance
Circuits, and two programmable relays.
The integral communicator transmits system status (alarms, troubles, AC loss, etc.) to UL-listed Central Stations via
the public switched telephone network. The control panel has a built in programmer and may also serve as a slave
communicator to a host panel. It also supervises all wiring, AC voltage, telephone line input voltage and battery level.
The MS-5024E offers the same features as the MS-5024 but allows connection to 220/240 VAC input.
1.1

Product Features

• Selectable as Fire Panel, Fire Panel/Communicator,
or Slave Communicator
• Programmable Zone ID: 2 Wire Smoke; Pull Station;
Normally Open Contact; Supervisory; Supervisory-
Auto Silence; Waterflow-Silenceable; Waterflow-
Non-Silenceable
• One Style D (Class A) Initiating Zone
• Four Style B (Class B) Initiating Zones
• 3.6 amps Usable Power
• Two NFPA Style Y (Class B) Notification
Appliance (bell) Circuits
• Built-in Programmer
• Built-in Voltmeter
• Telephone Line Active LED Indicators
• Communication Confirmation (Kissoff) LED
• Disable report by event
• Programmable Event Codes
• 24 Volt Operation
• Real Time Clock
• Trouble Reminder
• Alarm Verification
• Alarm Presignal
• RZA-5F Remote Annunciator (requires ADM-24
Annunciator Driver Module)
• Small Size 14.5" x 12.5" x 2.875"
• History File with 32 Event Storage
• Silence Inhibit per Notification Appliance Circuit
• Auto-Silence per Notification Appliance Circuit
• Touchtone/Rotary Dialing
• Programmable Make/Break Ratio
• Fuseless
• Number of dial attempts (5 min, 10 max)
• Programmable Channel ID (slave)
• Programmable Zone Delay (waterflow only)
• Two Form-C Programmable Relays
Note: Unless otherwise specified, MS-5024 shall be used in this manual to refer to both the MS-5024 and
MS-5024E Fire Control Communicators.
Technical Manuals Online! - http://www.tech-man.com

1.0 Product Description

50066 Rev D
5/2/97 P/N 50066:D
firealarmresources.com
Figure 1-1: Optional DP-5024
• Low AC Voltage Sense
• One Man Walk Test
• Optional Dead Front cover (DP-5024)
• CAC-5F Class A Converter module for
Initiating Device Circuits
• NACA-2F Class A Converter module for
Notification Appliance Circuits
7