With 1 Surveyor - FujiFilm PL-G.MAX Operation Manual

Pipeline and cable locator
Table of Contents

Advertisement

OPERATION IN EACH SITE SITUATION

6-1-2 With 1 surveyor

If the PL-G MAX will be used by just 1 person,
please follow these instructions:
Ensure there is enough battery power in the Transmitter.
Confirm that the Transmitter is set to IND
(Induction Mode)
Choose the frequency of Transmitter:
Either 83KHz or 27kHz may be used useful to confirm
the location of a pipeline.
Adjust the output power with the Output Power Control
Key between levels 2 and 5.
The Power Level should be chosen in accordance with
site conditions.
Place the Transmitter on the ground where the pipeline is
presumed to be buried.
Turn on the Receiver and select the same
frequency as the Transmitter (83kHz or 27kHz).
Have approximately 5 meters or more between the
Transmitter and the Receiver.
The Transmitter is must face the Receiver
as shown by the figure on the left
⑧ Locate the point where the Receiver displays the
maximum Bar Graph and Numerical Value as shown by
the left figures (A) (B) (C). Those points are the location
of the buried pipeline.
The Transmitter is required to be placed on the line shown
by the figure (A) (B) (C).
NOTE :
Ensure the transmitter is oriented correctly with the
pipeline.
- 36 -