Operation Of Receiver; Measurement Mode; Operational Procedure Of Receiver - FujiFilm PL-G.MAX Operation Manual

Pipeline and cable locator
Table of Contents

Advertisement

NOTE: Pull-up depth measurement is the most precise
NOTE : Use the same frequency for both the transmitter and receiver.
(a)
(c)
(b)

OPERATION OF RECEIVER

5-1
5-1-1
To locate the position of
pipeline correctly.
To grasp the change of depth
Continuous
of the pipeline.
Depth
Mode
To locate the pipeline over a
longer distance
By use of Sonde (probe),non-
metallic pipeline can be located.

Operational Procedure of Receiver

5-1-2
(a) Push the Power Switch Key
(b) Choose one of above modes
(c) Choose one frequency
Point 2
Point 1
Operational procedure
Measurement Mod
About 5 meters away from the transmitter, keep the
Point 3
direction and angle of the antenna perpendicular to
the pipeline as illustrated in next page, and move
sideways to pinpoint the pipeline.
Point 1. Operate the gain control switch to facilitate
the measurement.
Point 2. For night operation, press the backlight switch to illuminate
the LCD display.
Point 3. Press the volume switch until the volume is
appropriate for operation.
Large → Medium → Small → OFF
*The vibration function is turned ON/OFF by long press.
- 23 -