Installation Advice
※2m from Pipe is the limit
OPERATION IN EACH SITE SITUATION
⑤ Place the receiver where you detected a maximum point
and move the transmitter to where it was when
the receiver's bar graph and numeric value
reached maximum points.
(Variation of Bar graph & Level numeric value)
(POINT 1)
(POINT 2)
You may now perform pipeline detection work
* Adjust output of the transmitter.
* Select frequencies of the transmitter and receiver.
*Since maximum allowed distance between the transmitter
and buried pipeline is approx. 2 m, make sure to select the
detecting position
)
(Ex.1 distance from pipe is over 2 m)
030
※Over 2 m
(POINT 1)
20
(POINT 3)
(Ex.2 Transmitter is right on the buried pipe)
* Receiver sensitivity is weak
Adjust direction of the transmitter is perpendicular to direction of the pipe
- 35 -
(POINT 2)
80
(POINT 3)
20
* Receiver sensitivity is strong
080