15-2 Light Quantity of the Solder Recognition Light

1)
Check to make sure that both the solder recognition light and the OCC light go on with
manual control.
2)
Implement the "Adjustment of OCC light quantity" of the MS parameter.
When using an optional solder recognition light, adjust the reference current value so that
the LGET output result of (outer ring light) AVE_LVL is 210±2.
Substitute the obtained reference current value into the following formula and save the
calculated value to the reference current value.
Calculation formula: Reference current value × 2 = Value to be saved
* The jig to be used for adjustment of the solder recognition light is the same jig which is
used for adjustment of the standard angle light and vertical light.