4)
Remove the fixing bolts (hexagon socket head cap bolt with washer M5 L=12) to detach the
lower blade cover.
Remove the left and right lower blade covers.
5)
Attach a protective tape (duct tape, etc.) to the blade face (total length 346 mm) of the lower
blade.
Move the position of the movable blade to a position that is easy to work.
6)
Remove the fixing bolts (hexagon socket head cap bolt with washer M5 L=12) to detach the
lower blade.
Remove the left and right lower blade covers.
∗ Please wear a protective shield like a face shield to prepare for blade falling.