System electronic expansion valve(For cooling)
21
CN72
Electronic expansion valve(For EVI)
22
CN70
System electronic expansion valve1
23
CN60
Outdoor units communication or HMI communication port
24
CN61
Outdoor units communication or HMI communication port
25
CN64
Fan inverter module communication port
26
CN65
Compressor inverter module communication port
27
CN300
Program burn import (WizPro200RS programming device)
28
IC10
EEPROM chip
Temperature sensors input port.
T4: Outdoor ambient temperature sensor
29
CN1
T3A/T3B: Pipe temperature sensor of the condenser
T6A: Refrigerant inlet temperature of EVI plate heat exchanger
T6B: Refrigerant inlet temperature of EVI plate heat exchanger
30
CN16
System pressure sensor
Temperature sensors input port
Th: System suction temperature sensor
Taf2: Water side antifreeze temperature sensor
31
CN31
Two: Unit water outlet temperature sensor
Twi: Unit water inlet temperature sensor
Tw: Total water outlet temperature sensor when several units are connected in
parallel
Temperature sensors input port
Tp1 :DC inverter compressor 1 discharge temperature sensor
32
CN69
Tp2:DC inverter compressor 2 discharge temperature sensor
Tz: Coil final outlet temperature sensor
33
CN19
Low voltage protection switch
34
CN91
Three-phase protector output switch
35
CN58
Fan relay driver port
36
CN8
Remote function of cool/heat port
37
CN8
Remote function of on/off port
38
CN8
Water flow switch port
SW3: Up button
a) Select different menus when enter menu selection.
b) For spot inspection in conditions.
SW4: Down button
a) Select different menus when enter menu selection.
39
SW3-SW6
b) For spot inspection in conditions.
SW5: Menu button
Press to enter menu selection, short press to return to the previous menu.
SW6: OK button
Enter the submenu or confirm the function selected by short pressing.
40
USB
Program burn import (USB)
Digital tube
1) In case of stand-by, the address of the module is displayed;
41
DSP1/DSP2
2) In case of normal operation, 10. is displayed (10 is followed by dot).
3) In case of fault or protection, fault code or protection code is displayed.
S5: Dip switch
42
S5
S5-3: Normal control, valid for S5-3 OFF (factory default)
Remote control, valid for S5-3 ON.
DC12V
DC12V
DC12V
DC5V
DC5V
DC5V
DC5V
DC5V
DC5V
DC5V
DC5V
DC5V
DC5V
DC5V
DC5V
DC12V
DC12V
DC12V
DC12V
DC5V
DC5V
DC5V
DC5V
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scv-900ebScv-1400ebScv-1800eb

Table of Contents