OPTO-EDU A41.1950 Instruction Manual

Operating microscope, dual head, motor zoom, 3x-16x. for neurosurgery, brain surgery, ent

Advertisement

Quick Links

A41.1950
Operating Microscope, Dual Head,
Motor Zoom, 3x~16x. For Neurosurgery,
Brain Surgery, ENT
Instruction Manual
To ensure the safety and obtain satisfactory performance, please study this
instruction manual thoroughly before start to use your instrument.

Advertisement

Table of Contents
loading

Summary of Contents for OPTO-EDU A41.1950

  • Page 1 A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT Instruction Manual To ensure the safety and obtain satisfactory performance, please study this instruction manual thoroughly before start to use your instrument.
  • Page 2 A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT Thank you for using our A41.1950 Surgical Microscope ★ Preface The major content of "The Operation Manual of A41.1950 Surgical Microscope " consists of the following sections: Product overview, Method of Installing and Simply operation, Basic functions, Maintenances and troubleshooting, Technical specifications, and circuit diagram of this apparatus.
  • Page 3 A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT Section 5.3 ) Refer to Fig.1. Operation of the microscope frames ★ Statements The manufacturer is free of liability in the following cases: Apparatus damage or operation accident caused by improper operation or application to be carried out do not accord with the requirement of the Operation Manual or professional ability;...
  • Page 4 A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT Tighten the Tuning the knob clockwise knob will fix the can increase the balance force of cantilever in the cantilever; contrarily will range you need. reduce the balance force.
  • Page 5: Table Of Contents

    A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT Content Overview of the surgical microscope ............. 1 1.1 Acknowledgement .................. 1 General structures ................... 2 3 Installation ......................3 3.1 In The Package ..................3 3.2 Installation process of the operation microscope ........3 4 Functions of each part ..................
  • Page 6: Overview Of The Surgical Microscope

    A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT Overview of the surgical microscope 1.1 Acknowledgement Welcome to be our customer of medical instrument. The A41.1950 surgical microscope with A- class configuration can make your operation more relaxed and facilitated. The...
  • Page 7: General Structures

    A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT General structures Fig.2...
  • Page 8: Installation

    A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT 1.Foot controller 2. Focusing pedal 3.Zooming pedal 4. Obliquity rocker 5.Base 6. Base Locking knob 7. Power line 8.Foot controller socket 9. Fuse cover 10.Electric control box 11.Main stand...
  • Page 9 A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT ① ② ③ Fig.4 Step 3: Connect the socket (refer to Fig.5) (① connect the fan plug.② Connect controled cable. ③conect illumination power line,and tighten screw. ④ Connect the video plug.) and push the electronic-controlled box into the stand and then link and tighten the stand and the electronic-controlled box with 12 ball screws of M6 and washers firmly.
  • Page 10 A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT Fig 5 Step 4: Insert the Main body of the head (15) into the hole of the head joint (18) and fix it with the locking nut(21). As Fig.6 shows. Attention : Before you insert it(15), be sure that you have unscrew the locking knob(20).
  • Page 11 A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT Fig.7 Step 6: Installation of Assistant binoculor.take off lens cover side of beam splitter,align gap and insert assistant binoculor into beam splitter,and fasten locked ring. Fig 8...
  • Page 12: Functions Of Each Part

    A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT 24.Locking knob 27.force balance knob 26.cantalever Fig.9 Step 8: Correctly connect focusing cable (22), Obliquity control cable (23), foot controller socket (8) and the optical fiber (17) (Refer to Section 4.4:.Transversal arm); Insert lamp frame (29) into the transversal arm (30).
  • Page 13: Base

    A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT 4 Obliquity control rod 3 Zooming control pedal 2 focusing control pedal Fig.17 4.2 Base Refer to Fig 2. The "王" shaped base has reliable stability. When the operation arm extends to the maximum limit location, the entire instrument will not overturn.
  • Page 14: Cantalever

    A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT 4.5 Cantalever Refer to Fig.2. On the cantalever (26) a Force balancing knob (27) is arranged. Tuning the knob clockwise can increase the balance force of the cantilever, contrarily will reduce the balance force.
  • Page 15: Structure And Functions Of Microscope Head

    A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT 4.6 Structure and functions of microscope head Fig 19 Handle Axis of ro tation Window Stop Lens Facula modu la tion kn ob Zo o ming knob...
  • Page 16: Chief Operator Observed System

    A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT to rotate around axis of rotation,come to Y-direction movement,and keep head part of microscope to swing on horizontal position.left-right movement to come to X-direction swing.two-dimensional rotation are able to apply to brain and ENT surgery.
  • Page 17 A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT Fig 20 variable angle binocular tube 3 . Variable 2. Oblique p rism case Binocu lar angle e ye pie ce P rism ca se 4. Locked knob 5....
  • Page 18: Video Recording, Photography And Image Processing

    A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT 1.Eyepiece 2. Prism shell 3. Interface 4.8 Video recording, photography and image processing Through setting up a splitter on the zooming column and connecting CCD interface, distinct images can be seen on screen that means that one can carry out video recording.
  • Page 19: Operation Of The Control Panel

    A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT 5.2 Operation of the control panel Turn on Main power switch (10), the indicator lights; the instrument enters state of working preparation. Turn on power for light source and let the cooling fan start., push the left Brightness regulative button (11) on the panel, the brightness of cold light source increases step by step.
  • Page 20: Maintenance And Protect

    A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT Fig.23 6 Maintenance and protect The surgical microscope must be regularly maintained so as to reduce fault and ensure normal work of instrument.  Conditions for normal operation: Environmental temperature 10C~30C; Relative humidity ≤70%;...
  • Page 21: Technical Specifications (Adopt Adjustable-Pitch Observing System )

    A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT 7 Technical specifications (adopt adjustable-pitch observing system )  Forms of zooming: Variable power optical system with parallel optical path, stepless system turn -dru m zoo ming ...
  • Page 22: High Quality Service Promise

    A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT Table 2 Default diagnosing and debugging for A41.1950 Surgical Microscope (Refer to Fig.2) Common faults Diagnose and solution method  Check up the main power switch (10) whether it is on.
  • Page 23 A41.1950 Operating Microscope, Dual Head, Motor Zoom, 3x~16x. For Neurosurgery, Brain Surgery, ENT ① Sending the instrument to the user free of charge ② Provicing installation and commissioning free of charge. ③ Offering operational training free of charge. ④ When you purchase our surgical microscope, you will get the following services:...

Table of Contents