5. Turn on the power to the ice maker, then press "TIMER CLEAN" button on control
panel for more than 5 seconds, to enter the self-cleaning program. The water pump
runs for 8 minutes and stops for 3 minutes. The total duration time is 30 minutes for
one self-cleaning program.
During this process, the "CLEAN" light will always be on during this period and the
digit window will indicate the left time. Through this process, it will rinse the water
dividing pipe, evaporator, water pump, silicone pipe and water tank, etc.
6. After the self-cleaning program is complete, pull out the drainpipe of the water tank,
drain the cleaning solution down to the lower ice storage bin. Shake the unit slightly
to drain out all the cleaning solution completely, then reinstall the drainpipe to the
slot of the water tank.
7. Repeat steps 4-6 to clean the ice making assembly system again, then repeat two
more times.
8. Following the above procedure to clean the ice storage bin.
Tip: After this special cleaning procedure, you can return to regular ice making mode.
Discard the first batch of ice cubes.
• WARNING: The ice machine cleaner contains acids.
• DO NOT use or mix with any other solvent-based cleaner
products.
• Use rubber gloves to protect hands. Carefully read the material
safety instructions on the container of the ice machine cleaner.
Cleaning Suggestions
Daily Cleaning
The ice scoop, door and the water dividing pipe should be cleaned once per each day. At
the end of every day, rinse the ice scoop and wipe both sides of the door with a clean cloth.
Semi-Monthly Cleaning
The ice scoop, ice bin, water tank, the ice-full detecting plate and the surface of the
evaporator are to be cleaned semi-monthly according to interior cleaning program.
Semi-Annual Cleaning
All the components & surfaces exposed to water or ice cubes, like ice storage bin, water
tank, door, evaporator, water pump, silicone tube, water dividing pipe, etc. should be
cleaned using a nickel safe ice-machine cleaner every 6 months. They should be cleaned by
the qualified serviceman according to ice making assembly system cleaning program.