Encoder inputs X11 to X14
1 V
Cable length
PP
Input frequency: Max. 500 kHz
Subdivision factor: 4096-fold
Signal adjustment: Automatic
adjustment of offset, phase and
amplitude
Only for "Recording" operating mode and depends on
1)
firmware version (see the User's Manual for Application
Development)
The specified cable length applies when HEIDENHAIN
2)
cables are used; the supply voltage range of the
encoder must be maintained!
Measured-value trigger
Storage of measured value alternatively through exter-
nal or internal trigger (see User's Manual for Application
Development)
External
Signal via trigger input
Software command (via
Ethernet)
Internal
Timer
Reference position of axis 1
(absolute or delta value)
Traversing of reference marks
Trigger connections
Trigger input X31
D-sub connection, male, 9-pin
Differential inputs as per RS-485
(120 Ω terminating resistors can
be activated)
Trigger output X32
D-sub connection, female, 9-pin
4 differential outputs as per
RS-485 (any assignment of
the internal trigger sources
programmable)
Input voltage
U
Trigger,In
range
To GND: Min. -2 V, max. +10.0 V
U
Trigger,In+
Terminating resistor out:
Min. –10.0 V, max. +10.0 V
Terminating resistor in:
Min. –5.5 V, max. +5.5 V
Input resistance
In+ to In–
Terminating resistor out:
12.0 kΩ
Terminating resistor in:
Min. 105 Ω, max. 160 Ω
Data interface X4
Ethernet
RJ-45 connection
IEEE 802.3
10/100/1000 Mbps
Network address
Automatic assignment via DHCP or
manual configuration
32
: Max. 150 m
2)
–U
Trigger,In–
EIB 749: remote reset
Remote-Reset
2-pin connection
The input signals (Remote-
Reset +, Remote-Reset –) are
galvanically isolated from the
ground potential at the encoder
and trigger connections
Input voltage
U
Reset,In
range
Remote-Reset + measured
against Remote-Reset –:
Min. –0.5 V, max. +14.0 V
U
Reset,In,Lo
Reset = 0: Min. –0.5 V,
max. +0.8 V
U
Reset,In,Hi
Reset = 1: Min. +2.0 V,
max. +14.0 V
Current
I
: 10.0 mA
Reset
consumption
Ambient conditions
Operating
0 °C to 45 °C, no condensation
temperature
Storage
–20 °C to 70 °C, no condensation
temperature
General information
Directives
EMC Directive 2014/30/EU
Low Voltage Directive 2014/35/EU
Pollution degree
2
Protection
IP 20
EN 60529
Dimensions
See dimension drawings in Page 133 ff. in the Appendix.
All dimensions are in millimeters [mm].