Download Print this page

HEIDENHAIN EIB 700 Operating Instructions Manual page 27

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
5.4
Reset modes supported by the product
The product supports three different reset modes. The
modes differ in the firmware version loaded and in the
network settings.
Resets are initiated by the length of time the recessed reset
button is pressed. Resets can be initiated only after the
product has been switched on for at least five seconds.
Mode
Firmware version
loaded
1 User settings
Version of the most
recent firmware
update
2 Default setting
Default setting
with user's network
settings
3 Default setting with
Default setting
standard network
settings
The factory default setting for the firmware
and the standard network settings cannot
be changed by a firmware update.
Resetting the product to one of the two
factory default setting modes does not
delete the most recent firmware update.
The next time the product is switched on,
it boots the most recently stored firmware.
This is the firmware version that was loaded
during the most recent update. The user
settings will also be reloaded.
The firmware update is installed via a
connected PC and is described in the User's
Manual for Application Development, see
"Notes on reading the documentation",
Page 19.
Blinking pattern of the STATUS LED during a reset
While the reset button is being pressed, the reset modes
are indicated by the following blinking patterns of the
STATUS LED:
Mode 1:
Mode 2:
Mode 3:
HEIDENHAIN | EIB 700 | 03/2022
The product starts the respective reset mode once the
Reset button is released.
While the Reset button is being pressed, the respectively
selected reset mode is indicated by the different blinking
modes of the STATUS LED (activated by releasing the reset
button).
For information about the location of the reset button, see
"Rear panel", Page 24.
Network
Use
settings
User settings
Simple resetting. Takes place
each time the product is switched
on.
User settings
Apply if firmware was updated
incorrectly
Default
Execute if network settings are
settings
incorrect
EIB 749: Remote reset
Remote reset can be used for remote triggering of the
product reset. The remote reset functions in the same way
as the reset initiated by the reset button on the product.
Condition
t
Reset
< 5 s
> 6 s
< 9 s
> 10 s
29

Advertisement

loading

This manual is also suitable for:

Eib 741Eib 742Eib 749