8. Troubleshooting Guide

The following table contains fault symptoms, their possible causes and suggests
steps to rectify the problem. These may occur during initial installation and power
up.
Symptom
Pump keyboard does
not respond.
Mattress does not
inflate when the
system is switched
on.
Mattress inflates but
appears to be noisy as
if a leak has appeared
in the tube-set
connection with the
pump.
Mattress inflates but
doesn't appear to turn.
Mattress inflates but
only appears to turn to
one side.
Mattress turns but
then suddenly stops
mid cycle.
Possible Cause
Lock out is on
Lock out button LED
preventing set
illuminated.
up.
Pump is left in
If the pump is plugged into a
standby mode,
power socket, a dash will be
indicated by a
visible on the LED display to
single dash on
indicate standby mode.
the LED display.
Check status of LED display.
Blower failure
Check to ensure blower is
within pump unit.
generating airflow through
the manifold connector.
Hose-set
Check to ensure the hose
connection not
connector clicks into place.
correctly fitted.
Bolster/Sub-
Check plug is fitted correctly
Mattress plug not
in hose manifold.
fitted correctly or
failing.
Check integrity of plug.
No turn angle
Therapy Settings.
set.
Firm inflate
Maxflow
activated.
Dwelling in
Check status of LED display.
centre (check
turn time).
Therapy is set for
Ensure bilateral therapy
left or right turn
setting has been set.
only.
Both setting may
For bilateral turn ensure
not be
illuminated.
illuminated).
Maxflow
LED display showing '
activated.
Dwelling in
Check status of LED display.
centre (check
turn time).
Check
LED illuminated.
is activated (LED
F
'.
14
Action
Press and hold the lock
button until the LED
extinguishes.
Turn on the pump unit.
If the LED display is blank,
check integrity of power
supply at the wall socket.
If blower has failed call a
Service Engineer to replace
the blower/pump unit.
Re-connect hose connection
to pump, ensuring firm
fitment.
Ensure plug is firmly located.
Replace if neccesary.
Turn
Set
angles.
Press the
button to
deactivate, and enter
required therapy settings.
If LED display is illuminated
d
with '
' mattress is dwelling.
Bi-lateral
Enter
therapy
settings.
If not, press
to select
and ensure the LED
illuminates.
Press the
button to
deactivate, and set turn
angles.
If LED display is illuminated
d
with '
' mattress is dwelling.