Provision of Grace Period Before Supervisor Module Shutdown from Ejector Lever

Figure 44: Replace Air Filter
Step 2
Install the new door filters on both the front doors.
Step 3
Tighten the two quarter turn fasteners back on the doors.
Provision of Grace Period Before Supervisor Module Shutdown
from Ejector Lever
Earlier, unlatching the ejector lever from the latch lock immediately would trigger a graceful shutdown of the
Supervisor Module if the card is in the operational state. However, after enabling this feature, the Supervisor
Module has a grace period of 15 seconds before shutdown.
If the ejector lever is latched back within this grace period, then the card returns to the operational state. This
feature, therefore, provides the option of closing the ejector lever without triggering a shutdown. This feature
is especially useful when an ejector lever is accidentally unlatched.
This feature is supported only on a Supervisor Module.
If the ejector is unlatched when module is in a status other than operational state then the grace period feature
will not be supported.
Cisco Nexus 9808 NX-OS Mode Switch Hardware Installation Guide
74