Connecting DC Power to an EX2200 Switch

Copyright © 2018, Juniper Networks, Inc.
Figure 46: Connecting an AC Power Cord Retainer Clip to the AC Power Cord Inlet on an
EX2200 Switch
Retainer clip
Adjustment nut
NOTE:
The retainer brackets on your switch might be above and below the
power inlet rather than on either side.
Figure 47: Connecting an AC Power Cord to the AC Power Cord Inlet on an EX2200 Switch
Tighten
adjustment nut.
Connecting and Configuring an EX Series Switch (CLI Procedure) on page 114
Connecting and Configuring an EX Series Switch (J-Web Procedure) on page 117
Power Supply in EX2200 Switches on page 36
The power supply is built-in along the rear panel.
WARNING:
DC-powered switches are intended for installation only in a
restricted access location.
Before you begin connecting DC power to the switch, ensure that you have connected
earth ground to the switch chassis.
CAUTION:
Before you connect power to the switch, a licensed electrician
must attach a cable lug to the grounding and power cables that you supply.
A cable with an incorrectly attached lug can damage the switch (for example,
by causing a short circuit).