Warning code
Meanings
Inverter communicates
Warning 401
with Meter abnormal
Warning 404
EEPROM abnormal
Firmware version is not
Warning 405
consistent
11.4 I nverter fault
Warning code
Meanings
Error: 402
Output High DCI
Error: 404
Bus sample fault
Error: 405
Relay fault
Error: 408
Over Temperature
Error: 409
Bus over voltage
DSP communicates with
Error: 411
M3 abnormal
Error: 414
EEPROM fault.
The data sampled by the
Error: 417
DSP and redundant M3 is
not the same.
Error: 420
GFCI fault.
Suggestion
Check if the meter is on.
Check the inverter and the meter
connection is normal .
Restart the inverter. If the warning
still exist, please contact Growatt
customer service to replace the M3
board.
Uptate the right version firmware.
Suggestion
1.Restart inverter, if problem still
exist, Contact Growatt.
1.Restart inverter, if problem still
exist, Contact Growatt.
1.Restart inverter, if problem still exist,
Contact Growatt.
1.If the ambient temperature of
inverter is lower than 60°C, restart
inverter, if error message still exists,
contact Growatt.
1.Restart inverter, if problem still exist,
Contact Growatt.
1.Restart inverter, if problem still exist,
update the DSP&M3 firmware.
2.Change DSP board or M3 board, if
problem still exist, contact Growatt.
1.Restart inverter.
2.I f problem still exist,contact Growatt
1.Restart inverter.
2.I f problem still exist,contact
Growatt.
1.Restart inverter.
2.I f problem still exist,contact
Growatt.

Manufacturer Warranty

Please refer to the warranty card.
Decommissioning

13.1 Dismantling the Inverter

1. Disconnect the inverter as described in section.
2. Remove all connection cables from the inverter.
3.Screw off all projecting cable glands.
4.Lift the inverter off the bracket and unscrew the
bracket screws.
Danger of burn injuries due to hot enclosure parts!
Wait 20 minutes before disassembling until the housing has cooled
down.
CAUTION
13.2 Packing the Inverter
If possible, always pack the inverter in its original carton and secure it with tension belts.
If it is no longer available, you can also use an equivalent carton. The box must be
capable of being closed completely and made to support both the weight and the size of
the inverter.

13.3 Storing the Inverter

Store the inverter in a dry place where ambient temperatures are always between -25°C
and +60°C.
13.4 Disposing of the Inverter
Do not dispose of faulty inverters or accessories together with household
waste. Please accordance with the disposal regulations for electronic waste
which apply at the installation site at that time. Ensure that the old unit and,
where applicable, any accessories are disposed of in a proper manner.