Error
Description
1.Restart inverter.
Error 413 IGBT drive fault
2.If error message still exists,contact manufacturer.
1.Restart inverter
Error 414 EEPROM fault
2.If error message still exists, contact manufacturer.
I n t e r n a l p o w e r
1.Restart inverter.
Error 415
test fail(PV Power
2.If error message still exists,contact manufacturer.
low)
Over current
1.Restart inverter.
Error 416
protected by
2.If error message still exists,contact manufacturer.
software
The grid voltage
1.Restart the machine;
Error 417
sampling is
2.If the fault information still exists,contact the
inconsistent
manufacturer.
DSP and COM
1.Check the firmware version.
Error 418
firmware version
2.If error message still exists,contact manufacturer.
unmatch
Inconsistent
1.Restart the machine;
Error 419
leakage current
2.If the fault information still exists,contact the
sampling
manufacturer.
1: After shutdown,Check the leakage current module
GFCI Module
Error 420
2: If the error message still exists, contact
damage
manufacturer
C P L D
i s
1.Restart inverter.
Error 421
abnormal
2.If error message still exists,contact manufacturer.
sampling is
1.Restart inverter.
Error 422
inconsistent
2.If error message still exists,contact manufacturer.
A F C I s e l f - t e s t
1.Restart inverter
Error 425
fault
2.If error message still exists, contact manufacturer.
45
Suggest

Manufacturer warranty

Please refer to the warranty card.
Decommissioning
15.1 Dismantling the Inverter
1. Disconnect the inverter as described in section8.
2. Remove all connection cables from the inverter.
Danger of burn injuries due to hot enclosure parts!
Wait 20 minutes before disassembling until the housing has cooled
CAUTION
3. Screw off all projecting cable glands.
4. Lift the inverter off the bracket and unscrew the bracket
15.2 Packing the Inverter
If possible, always pack the inverter in its original carton and secure it with tension
belts. If it is no longer available, you can also use an equivalent carton. The box must
be capable of being closed completely and made to support both the weight and the
size of the inverter.
15.3 Storing the Inverter
Store the inverter in a dry place where ambient temperatures are always between -
25°C and +60°C.
15.4 Disposing of the Inverter
Do not dispose of faulty inverters or accessories together with household
waste. Please accordance with the disposal regulations for electronic
waste which apply at the installation site at that time. Ensure that the old
unit and, where applicable, any accessories are disposed of in a proper
14