General Time Channels - DAAB EP104 Instruction Manual

Hide thumbs Also See for EP104:
Table of Contents

Advertisement

General time channels.

No.
Name
C401** Running time readout, motor 1
C402** Running time readout, motor 2
C403** Setting limited running time (Not used with
encoder)
C412** Set limited opening, motor 1 with limit switch
C414** Set limited opening, motor 2 with limit switch
C422** Run-on time following limit switch open, motor 1
C423** Run-on time following limit switch closed, motor 1
C432** Run-on time following limit switch open, motor 2
C433** Run-on time following limit switch closed, motor 2
C436 Type of stop during run-on time when closing,
S
subordinated to C448 and C449
0
Time
1
Time or load guard
2
Time or safety edge
3
Time, load guard or safety edge
C448 Safety edge reverse during run-on time in the
S
closing movement, C423, C433, L117, L127
0
Function disabled
1
Safety edge reverse during run-on time
2
Safety edge reverse during run-on time and during the time in C492
C449 Reversing during run-on time with triggered load
S
guard, C423, C433, L117, L127
0
Disabled
1
Reversing in closing movement
C460
Delay of open motor 2 and close motor 1. Used
with magnetic locks or if the door halves overlap
C470
Delay before first motor starts, used for magnetic
locks that need to lose residual magnetisation
C492 Reverse delay if PHOTO, SL1 or SL2 or control
S
signal are activated.
C493 Reverse delay if safety edge or load guard are
S
activated
C494 Reverse time for protection in the opening
S
movement, safety edge and load guard
C495
Engagement time for brake, motor 1
C496
Engagement time for brake, motor 2
** = Only displayed if L001 and/or L002 are set to 2 or 3.
40
INSTRUCTION MANUAL DAAB AUTOMATIC CONTROLL UNIT EP104 4.08
Range
Factory Setting Ref.
000-999 seconds
000-999 seconds
001-999 seconds
001
00.3-99.9 seconds
05.0
00.3-99.9 seconds
05.0
0.00-7.99 seconds
0.00
0.00-7.99 seconds
0.00
0.00-7.99 seconds
0.00
0.00-7.99 seconds
0.00
0 - 3
3
0 - 2
2
0 - 1
1
0.1-9.9 seconds
0.1
0.00-0.99 seconds
0.00
0.1-4.0 seconds
0.8
0.03-2.00 seconds
0.10
0.1-2.0 seconds
1.0
00, 10-50 ms
00
00, 10-50 ms
00
Instruction manual edition 1 for EP104 version 4.08
page
29
29
29
31
32
33
33
33
28
26

Advertisement

Table of Contents
loading