Quick guide for commissioning of swing gates

• Prerequisites

The electrical installation is complete and drive units should be disengaged from the drive arm. Operate only one drive unit at
a time and start with drive unit 1. The type of motor power in C202 is set to 0, 3x400V with neutral. Limit switches must be
of encoder type. View mode, C999 is set to 2. The indications for photocell, stop circuit and 24V lights green

• Comissioning of drive unit 1

Direction of movement: Set L001 to 4, hold-to-run without limit switches. Check that the drive arm mounting is moving in
the right direction while pressing OPEN or CLOSE button on the control board. If the direction of movement is wrong, see
section "Connections" in the "Instruction Manual EP104".
Open and closed position: Engage gate leaf of drive unit 1 and set the positions for open and closed. After this is done
L001 should be set to 1, Encoder.
L110=1, Drive unit 1 Left position
Motor protection: Read out motor current in C251 under operation and apply appropriate values in C252 and C253.
Opening/Closing
Current(A)
150%
C252/C253
C251, Read out current
(50%)
C221
Current(A)
Opening/Closing
150%
C252/C253
(50%)
C221
Load guard: Set C999 to 3. A swing gate application usually does not require personal protection, if so C230 is set to
0.00. Set C033 to 3, impulse, to activate the load guard. Make sure that the settings of the C232 and C233 is low enough to
prevent material damage, but at the same time that it is guaranteed to open due to weather, wind and mechanical changes.
Power(kW)
Opening/Closing
C231, Power read out
C232/C233
C212, Load guard start delay
Safety edges: Check the safety edges on gate leaf 1 by pressing the safety edges during movement. Please note that the
safety function in opening direction is switched off in C131. If the safety edges are activated during closing movement the
gate should reverse to fully opened position, while in opening movement it should reverse to closed position during the time
in C494. A flashing indication at SE.C1 or SE.O1 means that the safety edge was activated but no longer is.
20
150%
E201
C252/C253
(50%)
Time
C221, Motor protection delay
150%
C251, Read out current
C252/C253
E206
(50%)
Time
C221, Motor protection delay
C232/C233
Reversing
-0,30kW
Time
C211, Load guard delay
INSTRUCTION MANUAL DAAB AUTOMATIC CONTROLL UNIT EP104 4.08
L123, Closed position
Current(A)
Opening/Closing
C251, Read out current
Opening/Closing
Current(A)
C251, Read out current
Power(kW)
Opening/Closing
C231, Power read out
C212
Instruction manual edition 1 for EP104 version 4.08
L120=2; Drive unit 2 Right position
L122, Open position
Time
Time
Time