INSTRUCTION MANUAL DAAB AUTOMATIC CONTROLL UNIT EP104 4.08

• Channel view options C999

By entering different values in the view options channel, EP104 will switch between different sets of channels. After power
on, C999 is shown as the first channel.
If C999=0 all channels are viewed.
If C999=1 only channels that differ from factory settings are viewed.
If C999=2 channels for supply voltage, motor protection and limit positions are shown. This view mode is used to set the
open and closed position.
If C999=3 only channels for safety edges, load guard, motor protection, gear ratio and limit switches are shown. This view
mode is used to set the load guard.
Instruction manual edition 1 for EP104 version 4.08
17