Photocell

No.
Name
C340
Safety function in closing movement
0
Disabled
1
Reverse to fully open
2
Stop with automatic restart of automatic closing
3
Stop, wait for new control signal or time in C520 and thereafter automatic closing.
C341
Safety during run-on time or disengagement angle
in closing movement.
0
Disabled when both halves are in run-on or disengagement angle
1
Activated according to C340
C342
Safety function in opening movement
0
Disabled
1
Reverse to fully closed.
2
Stop with automatic restart of automatic closing
3
Stop, wait for new control signal or time in C520 and thereafter automatic closing.
4
Stop with restart of opening
Check of external protection connected to PHOTO 0 - 1
C343
0
No check
1
Test of protection connected to PHOTO
C351
PHOTO closing
0
Disabled
1
Enabled and subordinated to C340
C354
Type of closing with PHOTO
1
Close immediately if PHOTO is clear
2
Open first then close if PHOTO is clear
Instruction manual edition 1 for EP104 version 4.08
Range
Factory Setting Ref.
0 – 3
1
0 - 1
1
0 – 4
0
1
0 – 1
0
1 – 2
2