Configuring the EP104

This section provides general instructions on how to change settings in the EP104.
Remember to discharge any static charge in your body by always touching an earthed connection before starting installation.

• General

All values are stored according to a list of channels (in the channel reference), with each channel corresponding to a particular
control parameter or value in the EP104.
The display can show a value up to four digits long, or a channel number with the prefix C, d, F, L, o, P or r, followed by three
digits.
The display can be used to show values as well as change settings – the value flashes while the setting is being changed.
If E appears followed by a number, this is an error message – see "Error messages". Note that the startup values
"EP-1" and "EP-2" are not error messages. When the power is connected, EP-1 appears when the unit controls one motor,
and EP-2 when the unit controls two motors.
The <┘ button switches between the value and the channel number and, in configuration mode, it saves the value.
The + button scrolls up the channel list in channel mode. In configuration mode, the button increases the value.
The - button scrolls down the channel list in channel mode. In configuration mode, the button reduces the value.
If no button is pressed in 90 seconds, the display switches to economy mode with reduced brightness. Press any button to
return to normal mode.
Display
C
Channel number for the EP104
nnn
d
Channel number for the vehicle
nnn
detector
F
Channel number for the frequency
nnn
converter
L
Channel number for the limit switch
nnn
o
Channel number for the output card
nnn
P
Channel number for programmable
nnn
inputs
r
Channel number for the wireless card
nnn
E
Error message (not EP-1 and EP-2)
nnn
nnnn
Readout of value
nnnn (flashing)
Value being changed
Button
+
Button to increase the channel or value
-
Button to decrease the channel or value
Switch between channel number and
<┘
value
Save/confirm the changed value
<┘
Switch between different channel
groups

• Readout of parameters in the EP104

Press the <┘ button so the display shows the channel number – a letter followed by digits.
Press the
button to quickly change between letters (channel groups).
Press the + or - button to step to the channel number you want.
Press the <┘ to show the value on the display.
Press the <┘ button again to exit and return to the channel number. Leave the unit in this mode – you cannot exit any further.

• Setting parameters in the EP104

Select the channel number according to the readout above.
Press the + button. The value starts flashing and is ready to be changed.
Press the + or - button to step to the value you want.
Press the <┘ button to save the value.
Press the <┘ button again to exit and return to the channel number. Leave the unit in this mode – you cannot exit any further.

• Locked settings

Settings in the different channels can be locked by service personnel so that they cannot be changed. Contact an authorised