• Signal reference

Safety edge 1, closing movement (SE.C1)
Safety edge 2, closing movement (SE.C2)
Safety edge 1, opening movement (SE.O1)
Safety edge 2, opening movement (SE.O2)
Power supply encoder or
limit switch common, motor 1
Encoder output, limit switch open motor 1
Limit switch closed motor 1
Power supply encoder or
limit switch common, motor 2
Encoder output, limit switch open motor 2
Limit switch closed motor 2
Shared programmable input 1 & 2
Programmable input 1, Open P160
Programmable input 2, Close P260
Shared programmable input 3 & 4
Programmable input 3, P360
Programmable input 4, P460
Shared programmable input 5 & 6
Programmable input 5, P560
Programmable input 6, P660
Input for photocell or
external loop detector
Output for magnetic lock
Output for self test
Unregulated 24VDC, 18-28VDC
Connection point
Connection point
Connection point
Connection point

• Low current

The safety circuit, safety edge or limit switch must not be connected to, or used for, any other function. If signals from
!
the EP104 are needed, a separate output card must be used.
The connection instructions are the same for all types of application, but not all signals may be needed.
If stop signals are unused, the associated input signals must be jumpered on the terminal block, see "Signal reference".
Note that the 24 V for the stop circuit must not be combined with other 24 V circuits.
!
18
Stop input 1
Stop input 2
Stop input 3
+
max 300mA
-
INSTRUCTION MANUAL DAAB AUTOMATIC CONTROLL UNIT EP104 4.08
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
+
29
Output
30
-
31
32
33
34
35
36
37
38
Instruction manual edition 1 for EP104 version 4.08
24VDC
24VDC
300mA

Advertisement

Table of Contents
loading