INSTRUCTION MANUAL DAAB AUTOMATIC CONTROLL UNIT EP104 4.08

General configuration channels

No.
Name
C033 Pulse/hold-to-run
S
0
Open and close with hold-to-run and load guard inactive
1
Open with pulse and close with hold-to-run and load guard active
2
Open with hold-to-run and close with pulse and load guard active
3
Open and close with pulse and load guard active
4
Open and close with hold-to-run and load guard active
5
Service mode, only internal open/close buttons with hold-to-run.
Enables L001/2 to be set to 4, operation without limit switch.
C063
Reverse priority during movement
0
None
1
Open
2
Close
3
Open and close
Instruction manual edition 1 for EP104 version 4.08
Range
Factory Setting Ref.
0 - 5
5
0 – 3
1