IQT-F116-R4*-V1
Operation
enhanced buffered write words EW
An attempt is made until successful, to write <WordNum> 32-bit words to the
address <WordAddr>. When successful a status 0 is sent. If there is no tag or a
tag leaves then a status 5 is sent. The command remains running.
Command:
Response:
Note!
Data collision
Only use the previous command if a single address is on the network.
Executing this command on more than one address will result in data collision.
single read fixcode SF
One attempt is made to read a fixcode.
Command:
Response:
enhanced buffered read fixcode EF
An attempt is made until successful to read a fixcode. When successful a status 0
is sent. If there is no tag or a tag leaves then a status 5 is sent. The command
remains running.
Command:
Response:
Note!
Data collision
Only use the previous command if a single address is on the network.
Executing this command on more than one address will result in data collision.
EW <DeviceNo> <WordAddr> <WordNum> <Data> <CHCK> <ETX>
<Status> <DeviceNo> <CHCK> <ETX>
SF <DeviceNo> <CHCK> <ETX>
<Status> <DeviceNo> <Data> <CHCK> <ETX>
EF <DeviceNo> <CHCK> <ETX>
<Status> <DeviceNo> <Data> <CHCK> <ETX>