8) Remove the Gas Valve by lifting upwards and outwards.
9) Secure the Valve Assembly by the 90 Elbow Fitting in a sturdy table vice.
Using a crescent wrench, loosen the valve from the Elbow fi tting.
** Do not place the valve in the vice by any other method than what is
shown. Holding the Valve in the vice will damage the Gas Valve and may
cause malfunction. **
10) Remove the 2 screws that hold the Right Side Valve Mounting Bracket
onto the Valve.
L540E-2 / HZI540E-2 Direct Vent Gas Insert
All manuals and user guides at all-guides.com
11) There is a provision in the Valve body casting that is designed to be
12) Place the Gas Valve into the machine vice using the provision as
13) Remove the 2 screws that secure the left side valve mounting bracket
14) Replace the gas valve with the new unit and re-assemble by reversing
15) Reconnect the gas and electrical supply to the unit. Once the unit has
used as a gripping point for assembly with other components. This is
the portion of the valve that can be placed in a machine vice.
described above. Do not over tighten the vice. Remove the Flare Fitting
from the gas outlet side of the valve.
from the gas valve.
disassembly steps 2-13.
be re-fi red, use a soapy water mixture to check all fi ttings and gas sup-
ply lines for gas leaks.