Profl Ame Remote System Gtmf With Fan; Wiring Diagram - Regency Fireplace Products L540E Owners & Installation Manual

Hide thumbs Also See for L540E:
Table of Contents

Advertisement

INSTALLATION
PROFLAME REMOTE SYSTEM GTMF WITH FAN (L540E / HZI540E)
120V AC
60 Hz
GTMF REMOTE SYSTEM - IMPORTANT: The 120V fan control module serves as the power source for this unit. The AA batteries in the
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
20
All manuals and user guides at all-guides.com

WIRING DIAGRAM

Proflame System
Configuration
885
886 GTMF
Wire Diagram
SureFire™ Switch
0.584.907
Thermostat
(Optional)
Ground
Black
Neutral
Green
Live
Ground
Black
Black
receiver only serve as a backup in case 120 volt power lost within the home.
See optional wall thermostat
installation in this manual.
Fan
Red
Fan Thermodisc
(normally open)
Black
Red
Caution: Ensure that the wires do not touch any