INSTALLATION
NOTE: Flue Plate Connector Gasket
must not be damaged or removed.
Care must be taken to ensure that this
gasket remains intact to prevent fl ue
1) Detach the Flue Connector Plate from the unit by removing the
Connector Plate Screws and sliding the Flue Connector Plate rearward
and off the unit.
Connector plate screws
2) Attach the Flue Liners onto the Flue Connector Plate using sealant and
gear clamps, then fasten with 3 screws per pipe.
See the section in this manual on Venting installation.
3) Position the unit in front of the fi replace opening, start the Flue Connec-
tor Plate into the Flue Connector Plate Guides.
Gear Clamps
Vent Connectors
Flue Connector
Slide Tool
Flue Connector
Screws
Flue Connector
Plate
Flue Connector
Plate Guides
Flue Connector
Plate Gasket
WARNING:
Failure to position the parts in accordance with these diagrams or failure
to use only parts specifi cally approved with this appliance may result in
property damage or personal injury.
14
All manuals and user guides at all-guides.com

FLUE / VENT INSTALLATION

leakage.
Flue Connector Plate
Intake Liner
Exhaust Liner
(L390E Shown)
4) Use the Flue Connector Slide Tool to slowly pull the Flue Connector
Plate forward as you move the Insert rearward into the Fireplace Chase.
Flue Connector Slide Tool
5) When the Flue Connector Plate is close to the front of the unit, engage
the Flue Connector Screws and carefully tighten the Flue Connector
Plate the fi nal amount.
** Make sure the Rear Tabs connect into their respective slots in the Flue
Connector Plate. Failure to do so will result in fl ue gas leakage and
degrade the operation of the unit ** (See diagram below of location.)
The Flue connection is complete when the Flue Connector Plate is fully
forward and the Rear Tabs are fully engaged.
6) Remove the Flue Connector Tool and store for future use.
Rear tabs fully engaged
(L390E Shown)
Properly installed Flue
Connector Plate
L540E-2 / HZI540E-2 Direct Vent Gas Insert