FAN MAINTENANCE - WITH GTMF REMOTE CONTROL

Note: To access the side and rear access panels both the gas and venting
will need to be disconnected(see vent/fl ue installation in this manual)
for proper removal.
There is no access to the blower from the front of this appliance.
Before you begin:
Shut off the gas supply to the unit.
Disconnect all electrical supply to the unit.
Always let the appliance cool to room temperature before servicing.
1) Remove 7 screws and loosen 5 screws along the bottom to remove fan
access panel -see Diagram 1a
Remove 4 screws to remove side access panel - see Diagram 1b
= Remove
= Loosen
2) Disconnect the fan wire harness through the rear panel. Disconnect 2 x
1/4" spade connectors to the fan terminals. Disconnect the ground lug to
the fan using the screw provided.
Strain Relief
Power Cord
Fan Controller
Wire Retainer
Fan Wire Harness
L540E-2 / HZI540E-2 Direct Vent Gas Insert
All manuals and user guides at all-guides.com
Diagram 1b
Diagram 1a
Fan Terminals
Ground Wire
Fan Mounting Bracket
Diagram 2
4) Remove 3 screws and remove the fan from the unit as shown below.
5) To install - reverse steps.
Electrical Grounding Instructions
This appliance is equipped with a three-prong
(grounding) plug for your protection against shock
hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug.
Fan
MAINTENANCE
Diagram 3
WARNING