Insert the key into the starter switch (5) and turn it to the RUN
position.
When switching the starter switch to the RUN position,
the fuel level indicator (1) and the coolant temperature
indicator (4) are tested for functionality. Both indica-
tors will light up for three seconds.
If the fuel level indicator (1) lights up, there are only 2.0 l of fuel left.
Refuel the excavator (page 109).
The engine oil pressure indicator (2) lights up and goes off after the
engine has started.
The charge lamp (3) lights up and goes off after the engine has
started.
The coolant temperature indicator (4) lights up and goes off after the
engine has started.
Under cold engine conditions:
Turn the starter switch to the RUN position for 10 to 15 sec-
onds, depending on the outside temperature.
Turn the starter switch to the START position and release it as
soon as the engine has started.
The switch will return automatically to the RUN position.
Some smoke is normal after starting the engine, even if it lasts a few seconds.
Set the throttle lever to idle speed and warm up the engine for approx. 5 minutes.
Operate the engine at low speed until operating temperature is reached.
At engine operating temperature:
Turn the starter switch to RUN for approx. 5 seconds.
Turn the starter switch to the START position and release it as soon as the engine has started.
The switch will return automatically to the RUN position.
Set the throttle lever to the desired speed.
Check the displays and indicators during operation (page 81).
80
K008-5
4
1
2
3
U10-5
4
1
2
3
Operation
5
5
W9215-8135-1
06/2021

Advertisement

Table of Contents
loading

This manual is also suitable for:

U10-5