GAS DRYER INSTALLATION REQUIREMENTS

Electrical Requirements
IMPORTANT: Observe all governing codes and ordinances.
This dryer is supplied without an electric cord and plug. It
must be connected by a Whirlpool authorized service person
to a single-phase electricity supply at the voltage shown
on the dataplate, using a suitable fixed wiring installation in
accordance with local and national wiring regulations.
A 3-wire circular cord of minimum conductor size 1.0 mm
cross-section area should be used.
A 10 A supply fuse should be used, and a switch with a clear
OFF marking having a contact separation in both poles that
provides full disconnection under over-voltage category
III conditions must be incorporated into the fixed wiring in
accordance with local wiring regulations. The dryer should
be positioned so that the disconnection switch is clearly
visible and easily accessible to the user. This disconnection
switch also provides the function of an emergency stop
control for the user.
A cord clamp bush is provided on the dryer, and should
be tightened on completion of wiring. The electrical mains
terminals are located behind the small rear access panel
(terminal block cover), and connections should be made
in accordance with the terminal markings. Remember to
replace the terminal access panel (terminal block cover).
NOTE: In accordance with the European EMC Directive
(2014/30/EU), the maximum electricity supply system
impedance to which the gas dryer should be connected is
declared to be 0.054 Ohm + j0.034 Ohm.
NOTE: Electrical safety standards: The manufacturer has
chosen compliance with IEC/EN.60335 standards as the
most appropriate for this product.
2
If codes permit and an additional ground bond wire is used, it
is recommended that a qualified electrician determine that the
ground bond path is adequate.
Recommended Earthing Method:
It is your responsibility to contact a qualified electrical installer
to ensure that the electrical installation is adequate and in
conformance with all local codes and ordinances.