IUH-F192-V1-*
Product Description
Ground connection
The ground connection of the read / write head is on the right side when the cable outlet faces
downward. Connect the protective earth conductor to the casing the with a crimp connector. To
ensure proper grounding, you must install the lock washer between the crimp and the housing.
1
1
Housing
2
Serrated lock washer
3
Crimp connector
4
Lock screw
Use a conductor cross section of at least 4 mm
Tighten the lock screw with a torque of 1.6 Nm ±0,4 Nm
2.4

Scope of Delivery

Read/write head
Quick start guide
2.5

Accessories

2.5.1

IDENTControl

The read/write head can be connected to Pepperl+Fuchs IDENTControl control interfaces.
Interface
4 read/write heads:
Ethernet
2 read/write heads:
PROFIBUS
Ethernet
EtherCAT
Serial
1 read/write head:
PROFIBUS
Ethernet
Serial
Table 2.1
2
3
4
Designation
IC-KP-B17-AIDA1
IC-KP2-2HB6-V15B
IC-KP2-2HB17-2V1D
IC-KP2-2HB21-2V1D
IC-KP2-2HRX-2V1
IC-KP2-1HB6-V15B
IC-KP2-1HB6-2V15B
IC-KP2-1HB17-2V1D
IC-KP2-1HRX-2V1
2
for the protective earth conductor.