Installing and connecting WLAN antennas
General
Depending on the inverter the WLAN antenna must be either installed in the in-
verter or mounted to the outside of the inverter.
IMPORTANT! Always follow the relevant operating instructions when opening an
inverter! Observe the safety rules!
Fronius IG,
Fronius IG Plus,
Fronius IG Plus
V, Fronius CL:
Installing and
Connecting An-
tennas
2
1
0,9 Nm
Use the double-sided adhesive
1
tape to fasten the mounting brack-
et to the outside of the inverter
housing or, if suitable for the an-
tenna cable, secure it in a position
near the inverter
IMPORTANT! The double-sided
adhesive tape only reaches its max-
imum bond strength after 24
hours.
IMPORTANT! The mounting brack-
et may not be screwed to the in-
verter housing.
It may however be fitted in a
nearby position. The relevant
screws are not included in the
scope of delivery and must be se-
lected by the installer.
Connect the antenna cable to the
2
antenna socket on the Fronius
Datamanager 2.0 plug-in card
Run the antenna cable out through
3
the DATCOM opening on the in-
verter
If possible, secure the cable with a
4
strain relief device
Close or seal the DATCOM opening
5
in accordance with the inverter op-
erating instructions
33