Installing Fronius Datamanager 2.0 – Overview
Safety
Danger due to incorrect operation.
This can result in severe personal injury and damage to property.
▶
▶
Installing Fronius Datamanager 2.0 requires knowledge of network technology.
Starting for the
The Fronius Solar.start app makes starting Fronius Datamanager 2.0 for the first
first time using
time much easier. The Fronius Solar.start app is available from the relevant app
the Fronius Sol-
store.
ar.start app
To start Fronius Datamanager 2.0 for the first time,
-
-
IMPORTANT! To establish a connection to Fronius Datamanager 2.0, the end
device in question (e.g., laptop, tablet) must be configured as follows:
-
1
2
42
WARNING!
Do not use the functions described here until you have fully read and under-
stood the Operating Instructions.
Do not use the functions described here until you have fully read and under-
stood all of the Operating Instructions of the system components, especially
the safety rules.
the Fronius Datamanager 2.0 plug-in card must be installed in the inverter,
or
there must be a Fronius Datamanager Box 2.0 in the Fronius Solar Net ring.
"Obtain an IP address automatically (DHCP)" must be activated
Connect the inverters with Fronius Datamanager 2.0 or Fronius Datamanager
Box 2.0 in Fronius Solar Net
IMPORTANT! Inverters Fronius IG, Fronius IG Plus, Fronius IG Plus V, Froni-
us IG Plus A, Fronius CL, Fronius CL USA, and Fronius IG 300–500 must al-
ways be located at the beginning or end of the Fronius Solar Net ring.
For Fronius Galvo/Fronius Symo/Fronius Primo only and when linking mul-
tiple inverters in Fronius Solar Net:
Set the Fronius Solar Net master/slave switch on the Fronius Datamanager
2.0 plug-in card as required
-
One inverter with Fronius Datamanager 2.0 = master
-
All other inverters with Fronius Datamanager 2.0 = slave (the LEDs on
the Fronius Datamanager 2.0 plug-in cards are off)