General Information For The Network Administrator; Requirements; General Firewall Settings - Fronius Datamanager 2.0 Operating Instructions Manual

Hide thumbs Also See for Datamanager 2.0:
Table of Contents

Advertisement

General information for the network administrat-
or

Requirements

Configuring a network for Fronius Datamanager 2.0 requires knowledge of net-
work technology.
If Fronius Datamanager 2.0 is being integrated into an existing network, the
Fronius Datamanager 2.0 address must be adapted to the network.
Example: network address range = 192.168.1.x, subnet mask = 255.255.255.0
-
-
-
If Fronius Datamanager 2.0 will be sending service messages and/or data to
Fronius Solar.web, then a gateway address and a DNS server address must also
be entered. Fronius Datamanager 2.0 uses the gateway address to access the in-
ternet. The IP address of the DSL router can be used as a gateway address, for
example.
IMPORTANT!
-
-
General Firewall
DSL routers mostly enable you to send data to the internet and, therefore, do not
Settings
normally have to be configured.
Server addresses for data transfer
If a firewall is used for outgoing connections, the following protocols, server ad-
dresses and ports must be allowed for successful data transfer:
-
-
-
-
-
-
-
-
-
-
-
-
-
If existing firewall rules block the connection to the Fronius system monitoring,
the following firewall rules must be added:
An IP address between 192.168.1.1 and 192.168.1.254 must be assigned to
Fronius Datamanager 2.0.
The IP address selected may not be already assigned in the network.
The subnet mask must correspond to the existing network (e.g.,
255.255.255.0).
Fronius Datamanager 2.0 may not have the same IP address as the PC/
laptop!
Fronius Datamanager 2.0 cannot connect itself to the internet. A router
must be used for a DSL connection to the internet.
Tcp fronius-se-iot-dm-1.azure.devices.net:8883
Tcp fronius-se-iot-dm-1.azure.devices.net:443
Tcp fronius-se-iot-dm-2.azure.devices.net:8883
Tcp fronius-se-iot-dm-2.azure.devices.net:443
Tcp fronius-se-iot-dm-1.telemetry.azure.devices.net:8883
Tcp fronius-se-iot-dm-1.telemetry.azure.devices.net:443
Tcp fronius-se-iot-dm-2.telemetry.azure.devices.net:8883
Tcp fronius-se-iot-dm-2.telemetry.azure.devices.net:443
Fdmp-solarweb.com:49049 (dm local port 54321)
Tcp http://www3.fronius.com:80
Tcp ftp://transfer.fronius.com:21
Tcp provisioning-lite.solarweb.com:443
Tcp froniusseiot.blob.core.windows.net:443
17