General information for the network administrator

Requirements
If Fronius Datamanager is being integrated into an existing network, the Fronius Datama-
nager address must be adapted to the network.
Example: Network address range = 192.168.1.x, subnet mask = 255.255.255.0
-
-
-
If Fronius Datamanager will be sending service messages and/or data to Fronius So-
lar.web, then a gateway address and a DNS server address must also be entered. Fronius
Datamanager uses the gateway address to access the Internet. The IP address of the DSL
router can be used as a gateway address, for example.
IMPORTANT!
-
-
If you are using the WLAN network connection, the Fronius Datamanager must be
equipped with a WLAN function and a WLAN antenna suitable for the inverter.
General Firewall
The firewall must be configured as follows in order to use the different Fronius Dataman-
Settings
ager functions:
Sending service messages
Connecting to datalogger via 'Fro-
nius Solar.web'
Connecting to datalogger via 'Fro-
nius Solar.access' or
'Fronius Solar.service'
Access to the Fronius Dataman-
ager web interface
Service messages are sent via Fronius Solar.web.
Configure the firewall so that the IP address of Fronius Datamanager can send data to port
49049/UDP from "fdmp.solarweb.com."
DSL routers mostly enable you to send data to the internet and, therefore, do not normally
have to be configured.
To access the Fronius Datamanager web interface outside of the LAN:
-
NOTE! Configuring a network for Fronius Datamanager requires knowledge of
network technology.
An IP address between 192.168.1.1 and 192.168.1.254 must be assigned to Fronius
Datamanager.
The IP address selected may not be already assigned in the network.
The subnet mask must correspond to the existing network (e.g. 255.255.255.0).
Fronius Datamanager may not have the same IP address as the PC/laptop!
Fronius Datamanager cannot connect to the Internet spontaneously. A router must be
used for a DSL connection to the Internet.
Configure the network router so that requests are forwarded to port 80/TCP on Fronius
Datamanager
49049/UDP
15015/TCP
output
input
x
-
x
-
-
x
-
-
80/TCP
input
-
-
x
x