TECHNICAL FEATURES

4
TECHNICAL FEATURES
ELECTRICAL FEATURES
Power
Supply voltage (Note 1)
Power consumption max.
Serial Interfaces
Main
Auxiliary
Baud rates
Inputs
Voltage max.
Input current max.
Outputs
V CE max.
Collector current max.
V CE saturation
Power dissipation max.
USER INTERFACE
LED indicators
10 to 30 Vdc
RS232, optocoupled RS485 half and full-duplex,
20 mA C.L.
150 to 115200 b.p.s
External Trigger, IN1
(optocoupled NPN or PNP)
User-defined OUT1, OUT2 and OUT3
(optocoupled open emitter, open collector)
40 mA continuous; 130 mA pulsed
1V at 10 mA max.
90 mW at 40 ° C (Ambient temp.)
Power ON, Good Read,
External Trigger , Data Transmission
2 W
RS232
30 Vdc
25 mA
40 Vdc
4
31