Section 7
Electrical System and Components
Troubleshooting Guide 3 amp/70 Watt Braking Stator (Continued)
Problem
1. Make sure lights are not burned out.
2. Disconnect the braking lead (green) from
the wiring harness.
No
Lights
measure voltage from braking lead to
Or
ground using an AC voltmeter.
Battery
Charging
3. With the engine stopped, measure the
(Braking
resistance from braking lead to ground
System
using an ohmmeter.
Test)
7.10
Test
Conclusion
1. Replace burned out lights.
2. If voltage is
is OK. Circuitry on unit that grounds
braking lead is shorted.
If voltage is
using an ohmmeter (Test 3).
3. If resistance is approximately
0.2-0.4 ohms, stator is OK.
If resistance is 0 ohms, stator is shorted.
Replace stator.
If resistance is
lighting lead is open. Replace stator.
, stator
, test stator
, stator or