Kohler Courage SV470 Service Manual page 112

Vertical crankshaft
Hide thumbs Also See for Courage SV470:
Table of Contents

Advertisement

9. Install the air cleaner base.
that the two metal spacers are in the air
cleaner base mounting holes and install
pin. Make sure the upper mounting tab is
positioned above the closure plate boss. See
Tab on Top of Closure Plate
Figure 10-64. Air Cleaner Base Upper Mounting
Tab Details.
Figure 10-65. Installing Air Cleaner Base.
b. Models with one screw and one mounting
stud only: Apply hand pressure to keep the
the alignment pin and install DRY the long
M6 thread forming screw – DO NOT OIL.
gaskets are still in proper position.
Figure 10-66. Installing Mounting Screw. (Models
with one stud and one screw).
Torque the screw to 8.0 N·m (70 in. lb.) into
a new hole, or 5.5 N·m (48 in. lb.) into a
used hole, do not over tighten. See Figure
be installed when the blower housing is
mounted.
Figure 10-67. Torquing Air Cleaner Fasteners.
air cleaner base.
Section 10
Reassembly
5.5 N·m (48 in. lb.).
10.19
10